background image

406 p

/n 3

04942

  O

p

M

 HRCP-Series

 H

eat

ed

 Cold P

ans

 

INSTALLATION 

NOTE:

  DO NOT discard 

the carton or other packing 
materials until you have 
inspected the appliance for 
hidden damage and tested it 
for proper operation. 
Refer to 

SHIPPING DAMAGE 

CLAIM PROCEDURE 

on the 

inside front cover of this 
manual. 

 

WARNING: 

RISK OF  
INJURY 

 
Installation procedures must 
be performed by a qualified 
technician with full knowledge 
of all applicable electrical and 
plumbing codes.  Failure can 
result in personal injury and 
property damage. 
 

IMPORTANT: 

Unit must remain in an upright 
position  during installation to 
prevent damage to the          
refrigeration system. 

 

IMPORTANT: 

Refrigeration system is air 
cooled.  Recommend louvered 
grills or equivalent openings 
on left and right side of       
condensing unit, with a      
minimum size of twice the 
condenser area (each      
opening) in order to provide 
adequate air circulation. 

 
IMPORTANT: 
DO NOT block air openings.  
Damage to the compressor 
will result.  Damage caused by 
improper air circulation is NOT 
covered by warranty.  

 

IMPORTANT: 

Access is required for the    
operation of the drain valve 
and for maintenance of the 
refrigeration unit.  Provide 
adequate access to the drain 
valve and refrigeration unit. 

 

 

UNPACKING & INSPECTION 

 

Carefully remove the appliance from the carton.  Remove all  
protective plastic film, packing materials and accessories from the 
Appliance before connecting electrical power or otherwise performing 
any installation procedure. 

 
Carefully read all instructions in this manual and the 

Installation 

Instruction Sheet

 packed with the appliance before starting any 

installation. 

 
Read and understand all labels and diagrams attached to the 
appliance. 

 
Carefully account for all components and accessories before 
discarding packing materials.  Store all accessories in a convenient 
place for later use. 

 

COMPONENTS 

 
2 ea.     

PAN RAIL, SIDE 

2 ea.     

PAN RAILS, END 

1 - 5 ea.    PAN RAILS, INTERMEDIATE ( qty differs with unit) 
1 ea. 

 

BACKFLOW PREVENTER ASSEMBLY 

1 ea.    

DRAIN VALVE 

1 ea.    

DRAIN SCREEN 

 

PREPARATION 

 
Cutout dimensions for tank units and control panels are listed on the 

Installation Instructions 

 provided with the unit. 

 
Countertop must be flat and level before the unit is installed.    After 
cutout is made, add stiffeners or bottom braces to counter as required 
to support unit weight. 

 
Provide louvered grills and service access below control panel. 

 
Verify that provided sealants are applied to the underside of the top 
flange prior to setting the unit into the cutout. 

 
After installation, apply a thin bead of food-grade silicone sealant 
around the flange to seal it to the counter. 
 

IMPORTANT: 

Unit flange must be sealed to the counter top.  Damage caused by 
leaks due to improper installation is NOT covered by warranty.  
 

 
For installation in plastic (e.g. Corian®) counter tops, the counter     
material must be protected from the heat of the warmer in order to   
prevent discoloration and/or deterioration.  The installer should contact 
the manufacturer or  distributor of the countertop material for specific 
installation instructions.  

 
Avoid storing flammable or combustible materials in, on or near the   
appliance.

 

Summary of Contents for HRCP-7200SL

Page 1: ...rson responsible for TRAINING OPERATORS of this appliance Additional manuals are available from your WELLS DEALER THIS MANUAL MUST BE READ AND UNDERSTOOD BY ALL PERSONS USING OR INSTALLING THIS APPLIANCE Contact your WELLS DEALER if you have any questions concerning installation operation or maintenance of this equipment OPERATION MANUAL HRCP Series DROP IN HOT AND COLD PANS MODELS HRCP 7200 HRCP ...

Page 2: ...LOSS OR DAMAGE Be certain that any visible loss or damage is noted on the freight bill or express receipt and that the note of loss or damage is signed by the delivery person 2 FILE CLAIM FOR DAMAGE IMMEDIATELY Regardless of the extent of the damage 3 CONCEALED LOSS OR DAMAGE if damage is unnoticed until the merchandise is unpacked notify the transportation company or carrier immediately and file ...

Page 3: ...anner which will ensure its optimum performance TABLE OF CONTENTS INTRODUCTION 1 MODEL VOLTS KW 1ø AMPS HP VOLTS 1ø AMPS REFRIGERANT POWER SUPPLY REQUIREMENT HRCP 7200 240 208 60Hz 2 5 1 9 10 4 9 0 1 4 120 60Hz 5 5 R 134a 3 wire L1 L2 N 10 AWG min 60ºC HRCP 7300 240 208 60Hz 4 0 3 0 16 7 14 4 1 3 120 60Hz 7 0 R 404a 3 wire L1 L2 N 10 AWG min 60ºC HRCP 7400 240 208 60Hz 5 0 3 8 20 8 18 1 1 2 120 60...

Page 4: ...FEATURES OPERATING CONTROLS 2 NOTE Model HRCP7300 shown Others are similar 406 p n 304942 OpM HRCP Series Heated Cold Pans ...

Page 5: ... Do not operate this appliance if the control panel is damaged Call your Authorized Wells Service Agent for service The technical content of this manual including any wiring diagrams schematics parts breakdown illustrations and or adjustment procedures is intended for use by qualified technical personnel Any procedure which requires the use of tools must be performed by a qualified technician This...

Page 6: ...l This appliance performance tested to NSF Standard 7 for storage of potentially hazardous foods This appliance meets NSF Standard 7 only when pan rails are installed in the lowest position HRCP units are ETL listed for US and Canada HRCP units are evaluated to UL standards 197 and 471 Components used in the manufacture of this unit are Underwriters Laboratory recognized AGENCY LISTING INFORMATION...

Page 7: ...e Carefully read all instructions in this manual and the Installation Instruction Sheet packed with the appliance before starting any installation Read and understand all labels and diagrams attached to the appliance Carefully account for all components and accessories before discarding packing materials Store all accessories in a convenient place for later use COMPONENTS 2 ea PAN RAIL SIDE 2 ea P...

Page 8: ...HRCP Series Heated Cold Pans INSTALLATION continued ELECTRICAL INSTALLATION 1 Refer to the nameplate Verify the electrical service power Voltage and phase must match the nameplate specifications Wiring the unit to the wrong voltage can severely damage the unit or cause noticeably decreased performance 2 Available electrical service amperage must meet or exceed the specifications listed on the spec...

Page 9: ...of control unit to the inlet of the backflow preventer NOTE While a backflow preventer is incorporated into the unit local codes may require an additional backflow preventer or vacuum breaker in the water inlet line 3 The unit must be connected to a potable cold water supply line with average pressure between 20 PSI and 90 PSI If your water pressure exceeds 90 PSI at anytime a pressure regulator m...

Page 10: ... supports b Install the end rails then any intermediate rails 5 Install pans or insets on the pan rails IMPORTANT Always use a pan or inset Never place food directly into the tank 6 Cover pans and insets to maintain consistent temperature Stir thick foods frequently SHUT DOWN PROCEDURE 1 Turn SELECTOR SWITCH to OFF The red HOT indicator will turn off 2 Remove all pans and insets 3 Open drain valve...

Page 11: ... IMPORTANT For NSF 7 operation use 12 x 20 x 4 deep pans and use the lower pan rail supports which are recessed 3 from tank top SHUT DOWN PROCEDURE 1 Turn SELECTOR SWITCH to OFF The white COLD indicator will turn off 2 Remove all pans and insets CAUTION ELECTRICAL SHOCK HAZARD DO NOT splash or pour water onto control panel or wiring HRCP units are performance tested to NSF Standard 4 for holding n...

Page 12: ...ils and element cover may be washed in a sink or dishwasher Allow to dry thoroughly then reinstall 5 Check drain screen clean if necessary and reinstall 6 Periodically inspect warmer flange to counter seal Reseal with food grade silicone sealant if necessary 7 Inspect tank and control panel for damage Contact your Authorized Wells Service Agency for repairs if water or grease contamination is susp...

Page 13: ... Authorized Wells Service Agency for repairs Unit won t cool COLD Mode Selector switch not set to COLD Set to COLD Tank too hot Allow to cool to 100ºF or less Condenser cooling louvers or coil plugged Clean condenser louvers and or coil Internal damage Contact Authorized Wells Service Agency for repairs Food not kept cold enough COLD Mode Food not chilled to start Add only pre chilled food Pan rai...

Page 14: ...n a linear motion along the longest axis of the equipment 4 Use only non chloride and non ammonia cleansers a DO NOT use any cleanser listed as chlorinated b DO NOT use any cleanser listing ammonia or ammonium in its contents c Contact your cleaning materials supplier for suitable alkaline cleansers 5 Keep your Wells hot and cold pan clean Clean frequently to avoid build up of hard stubborn stains...

Page 15: ...olve cleaner Cover tank 4 Allow solution to soak at least one hour or overnight for heavy scale buildup 5 After soak period turn control to OFF position 6 Drain hot water from pans Scrub with a plastic scouring pad Rinse thoroughly with hot water then dry 7 Refill tank and resume operation 8 Heavy scale buildup may require additional treatments FIRST AID EYES In case of contact immediately flush w...

Page 16: ...this operation IMPORTANT The fins of the condenser coil are delicate and easily damaged Use care to brush only in a vertical motion to avoid damaging the coil fins 4 Wipe the fan blades to remove accumulated lint 5 Reconnect to electrical power Refer to COLD Operation page 7 and test for proper operation CAUTION HOT SURFACE Exposed surfaces can be hot to the touch and may cause burns CAUTION INJUR...

Page 17: ...____ _________ EQUIPMENT MODEL NO _______________ EQUIPMENT SERIAL NO _______________ VOLTAGE check one 208 240 PARTS SERVICE 15 406 p n 304942 OpM HRCP Series Heated Cold Pans IMPORTANT Use only factory authorized service parts and replacement filters For factory authorized service or to order factory authorized replacement parts contact your Wells authorized service agency or call Wells Bloomfie...

Page 18: ...TION CUSTOMER SATISFACTION Wells Bloomfield proudly supports CFESA Commercial Food Equipment Service Association PRINTED IN UNITED STATES OF AMERICA WELLS BLOOMFIELD LLC 2 ERIK CIRCLE P O Box 280 Verdi NV 89439 www wellsbloomfield com telephone 775 689 5703 fax 775 689 5976 Commercial Food Equipment Service Association ...

Reviews:

Related manuals for HRCP-7200SL