M01
1B.02 2M-308015 Owners Manual for Bottom-Mount
Autofill W
armers
INSTALLATION
5
ELECTRICAL INSTALLATION
1.
Refer to the product nameplate. Verify the electrical service
power. Voltage and phase must match the nameplate
specifications. Wiring the warmer to the wrong voltage can
severely damage the unit or cause noticeably decreased
performance.
2.
Available electrical service amperage must meet or exceed the
specifications listed on the specification sheet provided with the
warmer.
3.
Warmer and control unit must be connected to an appropriate
building ground. Ground connection will be marked “GND” or
” “ .
NOTE:
Wire gauge, insulation type and temperature rating ,
as well as type, size and construction of conduit, must meet
or exceed applicable specifications of local codes and of the
National Electrical Code.
PLUMBING INSTALLATION
For use in the State of Massachusetts, this appliance must be
installed in compliance with
Massachusetts Fuel Gas and
Plumbing Code CMR 248.
1.
IMPORTANT: All plumbing installations must be performed by a
qualified plumber.
2.
For units equipped with a DRAIN LINE: Some jurisdictions may
require an approved air gap or other back-flow prevention device
in the drain. It is the responsibility of the plumber to determine
such requirement, to provide and properly install the required
device.
3.
For AUTOFILL units: Some jurisdictions may require an
approved back-flow preventer in the water supply line. It is the
responsibility of the plumber to determine such requirement,
and to provide and properly install the required device.
Autofill supply must be connected to a COLD WATER line only.
NOTE:
Damage caused
by leaks due to improper
installation is NOT covered by
warranty.
CAUTION:
SHOCk HAzARD
The ground lug of this
appliance must be connected
to a suitable building ground.
IMPORTANT:
Contact a licensed electrician
to install and connect electrical
power to the appliance.
IMPORTANT:
Damage due to being
connected to the wrong
voltage or phase is NOT
covered by warranty.
IMPORTANT:
Electrical
installation other than as
specified on the specification
sheet will void the UL listing,
and may void the warranty.
NOTE:
Plumb connections
must be made in compliance
with all Federal, State and
Local Plumbing Codes and
Ordinances.