M01

1B.02  2M-308015  Owners Manual for Bottom-Mount 

Autofill W

armers

FEATURES & OPERATING CONTROLS

2

A.

THERMOSTAT

1.

On thermostatically controlled warmers, power isapplied to the

heating element according to the control knob position and the

actual temperature at the temperature sensing thermobulb.

2.

The desired temperature is controlled by rotating the temperature

control knob.  The knob has a numeric scale, where higher

numbers correspond to higher temperature.

3.

On warmers equipped with an indicator light, the light will glow
when the thermostat is calling for heat (i.e. the element is
energized).

4.

The TEMPERATURE CONTROL KNOB will rotate approximately
300º, and will reach a “stop” at both ends.  The OFF position is 

marked.

NOTE: 

 The dial position is an indication of the temperature

setting.  Actual temperature will vary depending upon the type of 
product and food consistency.

B. MOUNTING

1. Bottom-mounted warmers require that the cutout be flanged to

provide a mounting means.

2.

See the Installation Instructions, supplied with the particular
appliance, for details.

C. DRAINS

1. Suffix “D” units (e.g. BMW206ULRTD/AF) have drains for each

pan, with each pan having an individual drain valve.

D. AUTOFILL

1.

On AUTOFILL BMW units, water level is automatically fed into the
pan whenever the thermostat is ON .

2.

Water level is sensed by a WATER LEVEL PROBE in the pan.

INDICATOR
LIGHT

TEMPERATURE
CONTROL
KNOB

IL2468

WATER LEVEL

SENSOR

IL2468

WA

TER LE

VEL

Summary of Contents for BMW206RTDU/AFU

Page 1: ...r TRAINING OPERATORS of this appliance Additional manuals are available from your WELLS DEALER THIS MANUAL MUST BE READ AND UNDERSTOOD BY ALL PERSONS USING OR INSTALLING THIS APPLIANCE Contact your WE...

Page 2: ...ult of normal use within the time period and limitations defined in this warranty will at Wells discretion have the parts replaced or repaired by Wells or a Wells authorized service agency THIS WARRAN...

Page 3: ...rchasing this Wells Bloomfield appliance Proper installation professional operation and consistent maintenance of this appliance will ensure that it gives you the very best performance and a long econ...

Page 4: ...NTROL KNOB will rotate approximately 300 and will reach a stop at both ends The OFF position is marked NOTE The dial position is an indication of the temperature setting Actual temperature will vary d...

Page 5: ...appliance use limitations and associated restrictions Operating instructions must be read and understood by all persons using or installing this appliance Cleanliness of this appliance is essential to...

Page 6: ...ng packing materials Store all accessories in a convenient place for later use INSTALLATION NOTES 1 Installation and start up of built in warmers MUST be performed by an authorized installation compan...

Page 7: ...med by a qualified plumber 2 For units equipped with a DRAIN LINE Some jurisdictions may require an approved air gap or other back flow prevention device in the drain It is the responsibility of the p...

Page 8: ...for the pan with the water level sensor is turned ON 4 Make sure the drain valve is fully closed before turning any thermostats ON 5 The autofill function is only activated when the far left thermosta...

Page 9: ...Warmer pans insets and other vessels are subject to a harsher environment Wells Manufacturing uses an very high quality stainless steel 304DDQ for our food warmer pans Even the highest quality stainle...

Page 10: ...nd water solution to neutralize all detergent cleanser residue 4 Inspect warmer flange to counter seal Reseal with food grade silicone sealant if necessary Failure to do so may allow grease and water...

Page 11: ...or covers accumulated scale 2 Heat water to maximum temperature 190 F or higher 3 Pour contents of one package of commercial delime cleaner into each warmer pan Stir to dissolve cleaner Turn heat cont...

Page 12: ...ed Wells Service Agency for repairs Warmer slow to heat Mineral deposits on pan acting as a insulator Clean pan s with delime cleaner Wired to wrong voltage Verify supply voltage must match voltage on...

Page 13: ...08 240V WS 503370 incl D8 303352 2V 47650 WS 503713 2T 45917 P2 40843 2J 35687 2R 40498 2K 31040 2K 47662 2K 48197 2K 48198 P2 306960 WS 50131 2C 41974 2I 40034 2I Z12311 2I Z12311 2K 34136X 2K 34136X...

Page 14: ...M011B 02 2M 308015 Owners Manual for Bottom Mount Autofill Warmers 16 WIRING DIAGRAM...

Page 15: ...T w lid WS 20587 11 QT ROUND INSET w lid WS 20908 11 QT ROUND INSET w hinged lid 5D 21057 DRAIN VALVE EXTENSION KIT extension from drain to counter front with remote handle for use with D models only...

Page 16: ...WELLS MANUFACTURING 265 Hobson Street Smithville Tennessee 37166 telephone 314 678 6314 fax 314 781 2714 www wells mfg com...

Reviews: