SENSOR A
SENSOR B
VS100C
P/N 24084_A
F2 0.125A 250V
F5 3A 250V
F1 20A 250V
J57
J28
J27
J90
J26
J12
J13
J29
J23
OZONE
PUMP 1
K4
K2
K5
J9
K6
K3
J11
K1
FOR SUPPLY CONNECTIONS, USE CONDUCTORS
SIZED ON THE BASIS OF 60°C AMPACITY BUT
RATED MINIMUM OF 90°C.
USE COPPER CONDUCTORS ONLY.
EMPLOYER UNIQUEMENT
DES CONDUCTEURS DE CUIVRE.
NEU (BLU)
L1 (BRN)
GROUND (GRN)
LOCATION
DEVICE
J23
NETZSTROMVERSORGUNG 2-GESCHW.-PUMPE 1 ALIMENTATION POMPE 1 A 2 VITESSES 2-SPEED PUMP 1
J29
OZONGENERATOR GENERATOROZONE OZONE GENERATOR
J20
BELEUCHTUNG ECLAIRAGE BAIN HYDRO SPA LIGHT
TORQUE RANGE FOR
MAIN TERMINAL BLOCK
(TB1):
27-30 IN. LBS.
(31.1-34.5 kg cm)
GROUND - TERRE - ERDE
GELB/GRUN - JAUNE/VERT
YELLOW/GREEN
CONTROL PANEL
TO J1
GS100
J43 MEM RESET
J6 TEST
HEATER
J1
J7
J20
12VAC-A
12VAC-B
J8
HI/LOW
T1
J10
115V 115V
230V
TB1
ON
LIGHT
J22
AUX F
J3
J18
PUMP TIMEOUTS TABLE
SWITCH 5 SWITCH 9
LOW SPEED HIGH SPEED
OFF
OFF
2 HOURS
15 MINUTES
ON
OFF
2 HOURS
30 MINUTES
OFF
ON
15 MINUTES 15 MINUTES
ON
ON
30 MINUTES 30 MINUTES
12-10-12
*SWITCH 1 IS NORMALLY OFF
ALL UNUSED SWITCHES SHOULD BE OFF
TEST MODE OFF*
UNUSED, P1, TEMP, LIGHT
DUPLEX PANEL
N/A MUST BE OFF
SEE PUMP TABLE
60HZ OPERATION
STD, ECON, SLEEP ALLOWED
DEGREES FAHRENHEIT
SEE PUMP TABLE
HIGH AMP - HEAT W/P1 HI
TEST MODE ON*
P1, LT, TEMP DOWN, TEMP UP
MINI PANEL
N/A MUST BE OFF
SEE PUMP TABLE
50HZ OPERATION
STANDARD MODE ONLY
DEGREES CELSIUS
SEE PUMP TABLE
LOW AMP - NO HEAT W/P1 HI
1
2
3
4
5
6
7
8
9
10
OFF POSITION
DIP SWITCH #
ON POSITION
BONDING GROUND
(INSTALLED)
HEATER
3.0 KW @ 230VAC
PN 56300
HEIZELEMENT
RADIATEUR
Wiring Configuration and DIP Settings
Wiring Configuration and DIP Settings
Setup 1 (As Manufactured)
• 230V Pump 1, 2-Speed
• 10V Spa Light
• 230V Ozone (with Pump 1 Low)
• 3.0kW @ 230VAC Heater
• VL260 Main Panel
g
Panel Button Assignments
1=Unused
2=Pump 1
3=Temp
4=Light
Panel Button Positions
1
2
3
4
1
4
2
3
,
p
1=Pump 1
2=Light
3=Temp Down
4=Temp Up
Typically Line voltage
Typically Line voltage for 2-speed pumps
Neutral (Common)
Ground
Note flat sides in connector
Board Connector Key
1
2
3
4
WARNING:
Main Power to system should be turned OFF BEFORE adjusting DIP switches.
WARNING:
Persistent Memory (J43) must be RESET to allow new DIP switch settings to take effect. (See Persistent Memory page)