background image

3

 

 

Dear user, 
Thank you for purchasing our leisure sanitary ware. To enable you to use this product safely 
and effectively, please read this Manual carefully before use.   

I.    Warning for using the steam room 

 

1. Please read this manual carefully before using, and guarantee the reliable grounding.   

2. For the sake of safe use, please don't lock the steam room.   

3. People after drinking, suffering from heart disease or hypertension, the elder and the 

pregnant women is not allowed to use this product.   

4. Any child or person with mental disability use this product must be with the company of a 

normal adult.   

5. Pay attention to anti-slip. 

6. Each time before use, check to confirm the power switch is turned on, and the leakage     

protection , the master valve for cold/hot water supplies . Remember to cut off the master 
supply each time after use.   

7. If you feel uncomfortable, please shut off the power immediately. 

8. Before turn on the faucet, please rotate the handle of cold/hot to the middle of H/C, and 

turn on the faucet, test the water temperature by finger, and then rotate the handle to adjust 
the temperature of water until feel comfortable. 

9. When using steam function, please don’t use the shower or water massage function. 

10. Keep your body away from the outlet of steam, to avoid scald. 

11. Never start the motor without water(if steam room with massage bathtub). 

12.Close the door and do not enter the steam shower when the sterilization is on. 

13.

 

Keep any flammable material or any object with the temperature of over 75

  away 

from the product surface, for it may damage the product and cause the fire. 

14. Don't cut off the power supply immediately each time after the use of the steam. Turn off 
the display first, and switch off the power only when the water remained inside the steam 
generator is completely drained off controlled by the computer to avoid any possible damage 
to the steam generator. 

15. Protect the electric wires from water, dampness, insects and mice when the product is 
unused for a long time. Shut off the master valve for power supply and the cut-off valves in 
the water pipeline immediately. Check the wires and grounding before the start of the 
product which is unused for a long time. 

16. It is required to shut off all functions of the product and wipe the water on hands before 
taking out the power plug. It is strictly forbidden to take out the plug of the active product or 
with a wet hand. 

Summary of Contents for WG-U683

Page 1: ...1 Steam Room Manual WG U683 R Model Size LxWxH mm Light Steam generator Fan Loudsp eaker faucet Top shower Hand shower WG U683 1200x850x2200 ...

Page 2: ...omputer panel 2 Top shower 8 Foot massage 14 Shower column 3 Hand shower 9 Hose of foot massage 15 Back jet 4 Shower pole 10 Tray 16 Steam outlet 5 Shampoo shelf 11 Ceiling light 6 Towel rail 12 Thermo mixer faucet 2 3 4 5 6 7 8 10 11 12 13 14 15 16 1 9 ...

Page 3: ...ter until feel comfortable 9 When using steam function please don t use the shower or water massage function 10 Keep your body away from the outlet of steam to avoid scald 11 Never start the motor without water if steam room with massage bathtub 12 Close the door and do not enter the steam shower when the sterilization is on 13 Keep any flammable material or any object with the temperature of over...

Page 4: ...arts Insert the wiring cords firmly and keep them away from any water pipe connector that may have water drips due to leakage Identify the connection symbols on the wiring cards before insertion as the error connection may damage the electrical parts in the steam room 2 Reliably connect the earth wire of the steam room to the indoor electrical grounding unit and make sure that it really works 3 Co...

Page 5: ...he flexible drain pipe to make sure of the fast and smooth drainage 3 In case of any leakage of the drainer stop it up with the rubber pad or silicone VI Installation steps A Two persons are required to assemble the unit B The glass is toughened safety glass Please take great care when handling and fitting the glass panels In particular avoid the glass edges coming into contact with hard surfaces ...

Page 6: ...8 pcs Install the horizontal and vertical frame 4x10mm screw 8 pcs Cut the seal according to the width of backwall put it on the top of backwall Cut the seal according to the width of backwall put it on the bottom of backwall This side is inside ...

Page 7: ...7 4 5 4x10mm screw 10 pcs fix backwall and aluminium 4x10mm screw 2 pcs each corner install the shower panel 6x30mm screw and nut 5 pcs each side and bottom 2 pcs ...

Page 8: ...f aluminium adjust the wheel to fit well finally fasten the screw of wheel Put the door glass on a table install the wheel don t fasten the screw of wheel too tightly now Put on the cover fasten screws 4x16mm 5pcs 6x30mm screw and nut 4 pcs ...

Page 9: ... door handle etc Install the fixed glass seal outside if the seal is too hard in winter you can drop this seal into hot water to make it soft Install door side seal in door glass two sides of door glass You can use a wood to help installing the seal Glass in this side ...

Page 10: ...fan light to light loudspeaker to loudspeaker fan light loudspeaker Connect the hoses to C Check the symbols on A or B depending on your shower model on your thermo mixers front plate to find the correct position for the hoses on the back side of the mixer ...

Page 11: ...h of the plug works well in this way press RESET with the power indicator on If the red light is still on when TEST is pressed or is not on as RESET is pressed it means that the leakage protection malfunctions or has any trouble Please call the professional to make the repair at this time 3 All functions of the steam room can be used so long as its power supply and water supply are checked as norm...

Page 12: ...12 ...

Page 13: ...oaction of the panel Otherwise it will lead to malfunction or trigger the panel lock 2 all function keys are located at the most convenient locations 3 When the panel is on power it will give out one sound of ring B functions introduction 1 spare massage 2 steaming 3 exhaust fan 4 FM 5 lighting 6 ozone disinfection 7 bluetooth 8 telephone 1 start up shut down and unlocking of panel startup ...

Page 14: ...perable 2 Instruction for operation After stratup the default location of cursor will be Rotate the shuttle switch to move the cursor After the cursor moves to a function press the shuttle switch or the function keys on the remote control to quickly turn on and turn off the function The icons will light up after functions are turned on and vanish after functions are turned off 3 operating instruct...

Page 15: ...ncrease the time or to decrease the time Timing range 5 50min Settings of temperature and time will automatically take effect in 3 seconds the system will exit the temperature and time setting mode Drainage 5 minutes after the shutdown of system the steam tank will drain water for 3 minutes 2 Spray Move the cursor to and press the shuttle switch The first press will turn on upper spray the second ...

Page 16: ...te control to turn on or turn off the ozone After startup icon light up and all other functions will be disabled except lighting function Emission of ozone will last for 10 minutes then the exhaust fan will automatically start and operate for 15 minutes 6 Radio Function Move the cursor and press the shuttle switch or press on the remote control to turn on or turn off the radio function Icon will l...

Page 17: ...ash for two seconds in this way at most 10 radio frequencies can be stored on different channels Frequency range 87 5 108 0MHz Switch of channels When the radio is turned on and the panel is unlocked move the cursor to press the shuttle switch rotate the shuttle switch or press on the remote control to switch channels and play programs on the stored radio channel 7 Bluetooth Turn on the system and...

Page 18: ... of phone calls the cursor can only move between non multimedia functions and phone After the cursor moves to a non telephone icon it will automatically return to the phone icon for no operation in five seconds Multimedia control keys on the remote control will be disabled during ringing and reception of calls When a phone call comes in touch to reject the call 9 Volume control In the radio and Bl...

Page 19: ...de The fourth press would return to the steam temperature setting As the system enters the volume adjustment mode would begin to flash on the LCD screen Operation of thermo mixer faucet Four way functions thermo mixer Foot massage Hand shower Top shower Back jet Turn on off water And adjust water volume Adjust water temperature ...

Page 20: ...ral water valve is not open B Failure of inlet valve control system C Failure in water level detection After the steam function is turned on the system will open water inlet after it detects shortage of water If the system shows no water after 10 seconds or the tank remains unfilled after 1 minute the system would report E10 fault as well as turn off steam function and inlet valve E16 Temperature ...

Page 21: ...g tool 8 Ask the professional to remove the deposits in the steam generator after a certain times of thermal circulation 9 Drain off the remaining water in the steam generator each time after use to prolong its service life 10 Make a test to check the leakage protection performance of the leakage switch once a month the leakage switch is of proper performance as it trips when the test key on the l...