1.

 

Wrap the heat blanket around the equipment. 

2.

 

Secure the heat blanket to the equipment using the loop and hook closures. 

3.

 

Close the Velcro

® 

seams. 

4.

 

If a thermostat is not included, connect the blanket cable directly to the power source. 

5.

 

If a thermostat is included, open a small section of the heat blanket seam, and then insert the 
thermostat sensor so that the thermostat sensor is between the heat blanket and the equipment. 
Secure the Velcro

®

 seam around the thermostat sensor to minimize heat loss. 

6.

 

If a thermostat is included, make the terminations from the heat blanket cable to the terminal 
strip of the thermostat, and then make the terminations from the terminal strip of the thermostat 
to the power source.  

 

7.

 

Turn ON the power source. As necessary, adjust the thermostat to the desired temperature. 

8.

 

The blanket is now in operation. 
 

 

After unpacking the unit, check the equipment for compliance and for any damage that 
may  have  occurred  during  shipment. 

Claims  for  damage  caused  during  shipment 

must be initiated by the receiver and directed to the shipping carrier.

 Welker

®

 is 

not responsible for any damage caused by mishandling by the shipping carrier. 

When sealing fittings with PTFE tape, refer to the proper sealing instructions for the 
tape used.  

Electrical terminations should only be installed by a qualified electrician.  

Conduit  seals  are  provided  for  the  cable  and  power  source  connections  when  a 
thermostat is included.  

Summary of Contents for HBAWEL9

Page 1: ...maintenance of the Welker equipment described above Correct operating and or installation techniques however are the responsibility of the end user Welker reserves the right to make changes to this and all products in order to improve performance and reliability This manual is intended to be used as a basic installation and operation guide for the Welker Heat Blanket HBAWEL9 HBAWEL15 For comprehen...

Page 2: ...IOM 080 Last Updated 10 20 2014 PART HBAWEL9 HBAWEL15 Page 2 of 7 Rev C TABLE OF CONTENTS Welker Welker Jet and WelkerScope are Registered Trademarks owned by Welker Inc ...

Page 3: ... is designed to maintain the set temperature and prevent temperature changes that would affect the integrity of the sample The blanket prevents unwanted condensation from accumulating inside sampling equipment Two thermal layers provide superior temperature protection and create a rugged flexible construction Loop and hook closures fasten the blanket to equipment and Velcro straps close the seams ...

Page 4: ...0VAC Australia 240VAC Area Classification NEC Class I Div 2 Groups B C and D IEC Zone 2 UL Listed Components T Rating T3 The specifications listed in this section are generalized for this equipment Welker can modify the equipment according to your company s needs However please note that the specifications may vary depending on the customization of your product ...

Page 5: ...e heat blanket cable to the terminal strip of the thermostat and then make the terminations from the terminal strip of the thermostat to the power source 7 Turn ON the power source As necessary adjust the thermostat to the desired temperature 8 The blanket is now in operation After unpacking the unit check the equipment for compliance and for any damage that may have occurred during shipment Claim...

Page 6: ... OFF all electrical power 2 Prior to performing maintenance on the equipment wrapped in the heat blanket remove the heat blanket from the equipment 3 The heat blanket should be wiped down with a clean moist cloth when maintenance is performed on the equipment 4 As necessary contact Welker for service options if the thermostat fails The heat blanket does not require maintenance ...

Page 7: ...on and Maintenance IOM Manuals suggested for use with this unit None Other Installation Operation and Maintenance IOM Manuals suggested for use with this unit None Welker drawings and schematics suggested for use with this unit None 13839 West Bellfort Street Sugar Land TX 77498 281 491 2331 Office welker com ...

Reviews: