50
WELGER RP 202 • RP 220 • RP 302 • RP 320
9. Wrapping
The following wrapping modes* can be selected
•
manual wrapping (twine and net)
•
automatic twine wrapping
•
automatic net wrapping
•
automatic combined wrapping
(only for
MASTER
and
PROFI
)
9.1.
"BALERCONTROL E Control Panel“
RP 202 • RP 302 CLASSIC
and
SPECIAL
RP 220 • RP 320 FARMER
The
BALERCONTROL E
control panel contains the following
functions and displays. (fig. 70):
No. Component
Function
1
Green LED
Correct power supply
2
Red LED
Set bale density reached
3 Yellow
LED
Automatic net wrapping selected.
(Flashes when the net clutch is in
operation)
4 Yellow LED
Automatic twine wrapping selected.
(Flashes when the twine motor is in
operation)
5 Button
Changes between manual and
automatic wrapping (manual: lights [3]
and [4] go out).
Depress for 5 seconds:
resets the
bale counter (DLC
1
) to zero.
6
Button
Trigger the net wrapping by hand
7
Button
Trigger the twine wrapping by hand
8 Display
Top row: non-resetting life time
counter (LTC
2
);
Bottom row: daily counter (DLC) can
be reset;
9 buzzer
(on back side)
Pre-selected bale density reached
1
DLC = Daily Counter
2
LTC = Life Time Counter
12 V
1
4
5
7
8
2
3
6
9
1742-43
fig. 70