Picture 8
The picture 8 shows press the Move Left Selector Menu
Button to Pre flow indicator light on, adjust the parameter
knob, the meter reads 0.1-1S adjustable.
Picture 9
The picture 9 shows press the Move Right Selector Menu
Button to Post flow indicator light on, adjust the parameter
knob, the meter reads0-15S adjustable.
Picture 10
The picture10 shows press the Move Right Selector Menu
Button to Base Amps indicator light on, adjust the
parameter knob, the meter reads 5-95% adjustable.
Picture 11
The picture11 shows press the Move Right Selector Menu
Button to End Amps indicator light on, adjust the parameter
knob, the meter reads 5-250A adjustable.
Picture 12
The picture12 shows press the Move Right Selector Menu
Button to Down Slope indicator light on, adjust the
parameter knob, the meter reads 0-25S adjustable.
0.1
0
5
5
0
Picture 13
The picture13 shows when choose under AC mode, press
the Move Right Selector Menu Button to AC balance
indicator light on, adjust the parameter knob, the meter
reads 30-70% adjustable.