background image

WELDMAN 

POWER PULSE DC TIG 200 HF / LIFT 

After setting the operating parameters it is recommended that the test gas by setting the switch (7) in the position of GAS. 

An important element is the 

clean surface welded:

An important element is the 

clean surface welded:

TIG welding is very sensitive to surface contamination of the metal. Because of that, before the welding process must be removed from the surface of the 
welded lubricants, paints, coatings and oxidized.

When these steps 

We start welding. 

When these steps 

We start welding. 

The arc welding device in takes place in a contactless manner (HF) - ignition by means of the ionizer, and closer to the electrode base material at a distance 
2-3mm and pressing in the handle or in the manner TIG contact (LIFT) by rubbing the electrodes of the welding. 

PARWELD handle PROFESSIONAL HR 17 allows you to increase / decrease the current operating buttons located on the handle, without interrupting the 
operator. 

After work by the operator follows

 ending welding 

as a result of the release button on the handle (welding current is gradually reduced and the arc goes out). Until 

After work by the operator follows

 ending welding 

as a result of the release button on the handle (welding current is gradually reduced and the arc goes out). Until 

After work by the operator follows

 ending welding 

as a result of the release button on the handle (welding current is gradually reduced and the arc goes out). Until 

the total disappearance of the bow handle can not be removed from the welded surface. Cooling of the weld surface of the cooling gas to prevent oxidation.

After you reboot the welding power supply unit has the operating parameters set last before switching off. 

MMA 

After selecting switch methods of work (7) MMA, the operator can set three operating parameters: welding current (turning multipurpose knob) and the value HOT 
START ARC FORCE. 
To do so, press the multifunction knob (1) illuminate the LED ARC FORCE, then hot start. Selection and adjustment of the operating parameters is 
carried out similarly while adjusting the parameters in TIG. To obtain high-quality welds

 remember to remove impurities

 with the work piece. In order 

carried out similarly while adjusting the parameters in TIG. To obtain high-quality welds

 remember to remove impurities

 with the work piece. In order 

carried out similarly while adjusting the parameters in TIG. To obtain high-quality welds

 remember to remove impurities

 with the work piece. In order 

to avoid irregularities during operation, should pay attention to the electrodes used were dry.

When these steps

 we start welding 

When these steps

 we start welding 

Ignition in the following by a welded by rubbing the electrode surface, and then lifting up the electrode. To avoid weld spatter should be used electrodes 
manufacturer's recommendations.

After completion of the welding welder must be left turned on for a short period in order to cool the unit by the fan. After completion of MMA welding 
should be removed from weld slag.

VII. TIPS FOR YOU 

VII. TIPS FOR YOU 

1) The basic types of connections TIG / MMA 

1) The basic types of connections TIG / MMA 

and butt 

b corner 

c overlapping 

d tee 

2) Tungsten electrodes recommended by the manufacturer 

2) Tungsten electrodes recommended by the manufacturer 

code 

the size of the 

electrodes 

RED 

GREEN 

GREY 

GOLD 

108 802 

108 812 

108 822 

108 832 

1,6x175 mm 

108 803 

108 813 

108 823 

108 833 

2,0x175 mm 

108 804 

108 814 

108 824 

108 834 

2,4x175 mm 

108 805 

108 815 

108 825 

108 835 

3,2x175 mm 

108 806 

108 816 

108 826 

108 836 

4,0x175 mm 

and 对接 接头

and 对接 接头

b 角 接 接头

b 角 接 接头

c 搭接 接头

c 搭接 接头

d T 形 接头

d T 形 接头

Summary of Contents for POWER DC TIG 200

Page 1: ...or loosened connections 4 Do not use cables with damaged insulation work and or loosened connections 5 Make sure that the power cord is not damaged 5 Make sure that the power cord is not damaged 6 Do...

Page 2: ...re that the welding work is adequate ventilation and that there are appropriate measures to 3 Make sure that the welding work is adequate ventilation and that there are appropriate measures to removal...

Page 3: ...FAN INSULATION CLASS IP23 DEGREE OF PROTECTION F DIMENSIONS 43x14x25cm WEIGHT 7 5 kg Duty cycle is based on the percentage distribution of 10 minutes for the time in which the machine can weld at rate...

Page 4: ...place not to get into it from welding spatter CONNECTING TO NETWORK Before the electrical connection check whether the data on the plate correspond to the values of the welding voltage and frequency...

Page 5: ...l operator preferences set the operating parameters The mode switch to select the mode flare holder 2 stroke or 4 stroke and arc ignition way contact contactless HF LIFT To access the settings menu of...

Page 6: ...st before switching off MMA After selecting switch methods of work 7 MMA the operator can set three operating parameters welding current turning multipurpose knob and the value HOT START ARC FORCE To...

Page 7: ...trode diameter mm 6 4 0 5 8 1 0 9 5 1 6 or 2 4 11 1 3 2 selected plant res ratio of the diameter of the gas nozzle to cupcake and the flow of shielding gas selected plant res ratio of the diameter of...

Page 8: ...s only valid if accompanied by a receipt or purchase invoice Difficulties arising from misuse negligence or breach of the device are not covered by the warranty The manufacturer is not liable for any...

Reviews: