WELDKAR WK MMA 4065 DC Instruction Manual Download Page 17

3. INSTALLATION

Please read these instructions carefully before using the 

device.

This must be carried out by qualified personnel. All 

connections must be made in accordance with the 

applicable regulations and in full compliance with the safety 

regulations (CEI Regulation 26-10 - CENELEC HD 427).

- Make sure that the mains voltage corresponds to the 

voltage indicated on the rating plate.

- When installing a plug, make sure it has a suitable capacity 

and connect the yellow/green conductor of the power cable 

to the grounding pin.

WARNING! Extension cables up to 30 m must be at least 2.5 

mm2 in diameter.

3.1 DESCRIPTION OF THE EQUIPMENT

1    Connection for remote control

2    Din cable connection (-)

3    Din Cable Connection (+)

4    Power Source Input: To connect a power source

5    On/Off switch: Checks the power supply

6    Parameter selection/control knob

7    Alarm lamp* 

8    Indicator light: This indicator lamp lights up when the machine  

      is. This indicator lamp lights up when the machine is switched    

      on and indicates that it is ready for use.

9    Digital multifunction display

10  LIFT TIG mode

11  MMA VRD 

12  MMA 

13  MMA hot start 

14  MMA welding current (Amps)

15  MMA arc force (Arc Force)

16  Welding output mode button: Sets the power source to MMA, 

      MMA VRD or Lift TIG mode.

3.2 MMA-WELDING

- This welding machine is suitable for welding all types of 

electrodes, with the exception of cellulose electrodes.

- Make sure that the switch (12) is set to On and then 

connect the welding cables, ensuring that the polarity 

prescribed by the manufacturer of the electrodes used is 

respected.
VERY IMPORTANT:

Connect the ground cable with the workpiece clamp 

(ground clamp) to the negative Din-Coupling (10) and 

ensure good contact to ensure trouble-free operation of 

the equipment and to avoid voltage drops with the 

workpiece.
- Close the electrode cable with the electrode base 

(welding tongs) to the positive Din-Coupling (11). 

- Check that the correct mains voltage corresponds to the 

welding machine.

- Do not touch the welding torch or electrode holder and 

the ground connection at the same time.

- Set the selector switch (5) to MMA (right).

- Switch the machine on with the switch (12).

- Set the welding current with button (1).
Never forget to switch off the machine and remove the 

electrode from the clamp after welding.

3.3 TIG WELDING

- This welding machine is suitable for Tig welding according 

to the scratch principle of the following materials with the 

TIG process: stainless steel, iron, copper.

- Check that the correct mains voltage corresponds to the 

welding machine.

- Do not touch the welding torch or electrode clamp holder 

and the ground connection at the same time.

- Connect the ground cable to the positive pole (+) of the 

welding machine and connect the clamp to the workpiece, 

as close to the welding point as possible.

For TIG welding, use a Lift Arc TIG torch with built-in 

throttle valve.

- Connect the Tig Welding Torch to the negative pole (-) of 

the welding machine.

- Connect the gas hose to the tulle of the pressure 

regulator, which in turn is connected to an ARGON cylinder.

- Press the Tig torch switch and adjust the gas flow.

- Use a tungsten electrode suitable for steel and stainless 

steel e.g. an electrode with 2% cerium, with a diameter of 

1.6 mm (1/16").

- Set the selector switch (7) to TIG (left).

- Switch the machine on with the switch (12).

- Set the welding current with button (1).

- Bring the welding arc into contact with the workpiece and 

make firm and quick movements.

Do not forget to switch off the machine and close the gas 

cylinder valve after welding.

DC INVERTER WELDER 

WK MMA 

4065

Summary of Contents for WK MMA 4065 DC

Page 1: ...www weldkar com INVERTER WELDKAR WK MMA 4065 DC GEBRUIKSAANWIJZING welding equipment...

Page 2: ...Deel 2 Elektrisch ALLE INSTALLATIE BEDIENINGS ONDERHOUDS EN REPARATIEWERKZAAMHEDEN MOGEN ALLEEN DOOR GEKWALIFICEERDE PERSONEN WORDEN UITGEVOERD Hoewel de informatie in deze handleiding het beste oorde...

Page 3: ...een veiligheidsharnas om vallen te voorkomen bij het werken boven het vloerniveau 15 Houd alle panelen en afdekkingen goed op hun plaats WAARSCHUWING BOOGSTRALEN kunnen de ogen en de huid verbranden...

Page 4: ...ichaamsbescherming om de huid te beschermen WAARSCHUWING Indien beschadigd kunnen GASFLESSEN ontploffen Schermgasflessen bevatten gas onder hoge druk Indien beschadigd zal een gasfles kunnen explodere...

Page 5: ...e velden rondom de kabels en de generatoren De magnetische velden geproduceerd door hoge stroom kunnen de functionering van pacemakers be nvloeden De dragers van vitale elektronische apparatuur pacema...

Page 6: ...tlastijd Puntlasmodus Indrukken om de draadtoevoer en het lassen te starten loslaten om te stoppen Doorblazen van gas Inches per minuut Meter per minuut Laspistool Burnback tijd 4 Staps trekkerbedieni...

Page 7: ...n DE MACHINE MAG NIET WORDEN GEBRUIKT OM LEIDINGEN TE ONTDOOIEN 2 2TECHNISCHE SPECIFICATIES Model WK MMA 4065 DC Netspanning 3 fase 300 400 440V Frequentie 50 60 Hz Lasstroombereik 20 400 A TIG MMA Af...

Page 8: ...ay 10 LIFT TIG modus 11 MMA VRD 12 MMA 13 MMA hot start 14 MMA lasstroom Amp re 15 MMA boogkracht Arc Force 16 Lasuitgangsmodusknop Stelt de stroombron in op MMA MMA VRD of Lift TIG modus 3 2MMA LASSE...

Page 9: ...g of de onderdelen die tijdens de functionering verhit raken Hermonteer alle klemringen op de oorspronkelijke wijze om een verbinding tussen de primaire en secundaire te voorkomen als een draad breekt...

Page 10: ...DC INVERTER WK MMA 4065 5 ELEKTRISCH SCHEMA 10...

Page 11: ...11...

Page 12: ...INSTRUCTION MANUAL DC INVERTER WELDER WK MMA 4065 welding equipment www weldkar com...

Page 13: ...elding process produce intense heat and strong ultraviolet rays that can burn eyes and skin Noise from some processes can damage hearing 1 Wear a welding helmet fitted with a proper shade of filter to...

Page 14: ...d equipment and Safety Standards WARNING MOVING PARTS can cause injury Moving parts such as fans rotors and belts can cut fingers and hands and catch loose clothing 1 Keep all doors panels covers and...

Page 15: ...cycles sec Frequency Negative Positive Direct Current DC Protective Earth Ground Line Line Connection Auxiliary Power Receptacle Rating Auxiliary Power Art A 10663_AB 115V 15A t t1 t2 X IPM MPM t V F...

Page 16: ...TIG MMA Fuse 27A 35A Switch on time 60 400A 60 400A 100 325A 100 325A Zero load voltage 12 volt 55 volt Protection class IP23 Insulation class H Electrode diameter 1 6 6 0 mm Weight 19 kg Dimensions 4...

Page 17: ...nd ensure good contact to ensure trouble free operation of the equipment and to avoid voltage drops with the workpiece Close the electrode cable with the electrode base welding tongs to the positive D...

Page 18: ...ted metal dust with compressed air d d d The power lamp lights up the fan is running normally but there is no welding current Hot welding clamp Large sparks occur during welding Check that the power s...

Page 19: ...5 ELECTRICAL DIAGRAM DC INVERTER WELDER WK MMA 4065...

Page 20: ......

Page 21: ...DC INVERTER WELDER WK MMA 4065...

Page 22: ...www weldkar com INVERTER WELDKAR WK MMA 4065 DC GEBRAUCHSANWEISUNG welding equipment...

Page 23: ...Elektrotechnik ALLE INSTALLATIONS BETRIEBS WARTUNGS UND REPARATURARBEITEN D RFEN NUR VON QUALIFIZIERTEN PERSONEN DURCHGEF HRT WERDEN Die in diesem Handbuch enthaltenen Informationen wurden vom Herstel...

Page 24: ...enden Sie Ger te mit einem Gleichstromausgang 14 Tragen Sie bei Arbeiten ber dem Boden einen Sicherheitsgurt um St rze zu vermeiden 15 Lassen Sie alle Platten und Abdeckungen an ihrem Platz WARNUNG BO...

Page 25: ...zt Beim Abk hlen von Schwei n hten kann Schlacke austreten 1 Tragen Sie einen zugelassenen Schwei erschutz oder eine Schutzbrille Seitliche Schutzvorrichtungen werden empfohlen 2 Tragen Sie einen geei...

Page 26: ...elektromagnetische Felder EMF Der Schwei oder Schneidstrom erzeugt elektromagnetische Felder um die Kabel und die Generatoren Die durch Starkstrom erzeugten Magnetfelder k nnen die Funktion von Herzs...

Page 27: ...um den Drahtvorschub zu aktivieren und um mit dem Schwei en zu beginnen loslassen um zu stoppen Sp lung von Gas Zentimeter pro Minute Meter pro Minute Schwei pistole R ckbrennzeit 4 stufig Abzugskontr...

Page 28: ...mationen zur korrekten und sicheren Verwendung des Ger ts sowie Anweisungen wie Sie die gr tm gliche Effizienz und Qualit t aus Ihrer Stromquelle herausholen k nnen DIE MASCHINE DARF NICHT ZUM AUFTAUE...

Page 29: ...mversorgung Diese Diese Signallampe leuchtet auf wenn das Ger t eingeschaltet wird und zeigt an dass es betriebsbereit ist 5 MMA 6 MMA VRD 7 HEBEN WIG 8 Einstellung f r Hei start Siehe 4 4 9 Einstellu...

Page 30: ...s ein Draht bricht oder sich l st Montieren Sie die Schrauben mit den Zahnringen wieder in der urspr nglichen Weise Montieren Sie die Schrauben mit den Zahnringen wieder in der urspr nglichen Weise 4...

Page 31: ...DC INVERTER WK MMA 4065 5 Elektrischer Schaltplan 10...

Page 32: ...11...

Page 33: ...www weldkar com welding equipment...

Reviews: