background image

Page 16

990008 Rev. H

Summary of Contents for Kreativ Mach 5.0

Page 1: ...sold to a licensed dentist Copyright Notice Copyright 1999 Kreativ Inc All rights reserved No part of this manual may be reproduced without written permission from Kreativ Inc Manufactured by Kreativ...

Page 2: ...PLY REQUIREMENTS MACH 5 0 ONLY 18 ELECTRICAL REQUIREMENTS 18 MACH 5 0 D ENTAL CHAIR PNEUMATIC INTEGRATION 18 5 INSTALLATION AND UNIT CHECKOUT 20 PRE INSTALLATION REQUIREMENTS 20 UNIT CHECKOUT 20 FILLI...

Page 3: ...PPED HANDPIECE ASSEMBLIES 31 ABRASIVES GAMMAPURE GAMMA TREATED 31 ORDERING INFORMATION 32 10 RECYCLING 34 RECYCLING INSTRUCTIONS FOR DEVICE ACCESSORIES AND PACKAGING 34 ENVIRONMENTALLY RELEVANT MATERI...

Page 4: ...horoughly familiar with this manual Purpose of this Manual This manual should be thoroughly studied before installing and using the equipment Please call your nearest authorized Welch Allyn Kreativ se...

Page 5: ...le levels controlled by the user Particle Energy minimum is 30 maximum is 120 see Table 1 for psi to kPa conversion in Chapter 3 Beam Intensity minimum powder is 0 maximum is powder 10 Remote Control...

Page 6: ...es in sizes angles and cutting capabilities Locked doors to prevent unauthorized access Specifications Power Requirements Domestic Mach 5 0 100 127 V 60 Hz 400 mA Mach 5 0 PLUS 100 127 V 60 Hz 6 5 A I...

Page 7: ...ic pressure range 7 25 psia 50 kPa to 15 37 psia 106 kPa Equipment Classification The Mach 5 0 and Mach 5 0 PLUS systems are Class I devices requiring an electrical earth ground These devices are clas...

Page 8: ...ated While the abrasive stream will not cut the gingival tissue it may irritate it All Kreativ Mach 5 0 and Mach 5 0 PLUS accessories which come into contact with the patient should be sterilized prio...

Page 9: ...es supplied by other manufacturers may result in damage to the unit and will void the factory warranty Use only clean dry air Make sure that your air compressor system utilizes air dryer filter system...

Page 10: ...Labels Alternating current Protective earth ground Attention consult accompanying documents Off power disconnection from the mains On power connection to the mains Type B equipment defines the degree...

Page 11: ...odule to be remotely located up to 10 feet from the main unit The connector to the air supply is located on the rear of the instrument 2 A mounting plate with clamp is supplied with the Mach 5 0 and t...

Page 12: ...es the relative amount of abrasive powder that is being delivered to the handpiece nozzle Warning Indicators indicate the type of problem when operational problems occur Particle Energy indicates the...

Page 13: ...Page 13 990008 Rev H Drawings of Controls Figure 1...

Page 14: ...Page 14 990008 Rev H Figure 2...

Page 15: ...Mixing Chamber With the footswitch depressed the Abrasive Control Valve is opened This opens the path for the stream of powder particles from the Mixing Chamber to the nozzle The Beam Intensity and Pa...

Page 16: ...Page 16 990008 Rev H...

Page 17: ...sult your Kreativ Inc dealer The Mach 5 0 PLUS instrument has a built in air compressor thus eliminating the need for connection to an external air supply It is necessary to connect to a properly grou...

Page 18: ...epairs for such damage are at the customer s expense Electrical Requirements Reference the Specifications section of Chapter 1 of this manual for the power requirements of the unit The power requireme...

Page 19: ...h 5 0 Install male quick disconnect to end and connect to Mach 5 0 Foot Switch port 7 Open valve from compressor to restore pressure to the Dental chair unit 8 Check new connections for leaks Caution...

Page 20: ...equirements Refer to the Site Preparation information supplied by Kreativ Ideally air for the Mach 5 0 will be obtained by placing a Tee fitting prior to the final regulator at the operatory but after...

Page 21: ...e eyewear when using the Kreativ Mach 5 0 or Mach 5 0 PLUS systems and do not direct the nozzle towards the face when operating the footswitch WARNING Before filling the mixing chamber with the Air Co...

Page 22: ...ouch the Air control to ON Lift the handpiece from the cradle If the handpiece is not in the cradle the microswitch on top of the Remote must be depressed before the footswitch is activated Press the...

Page 23: ...are free of powder and the lid gasket is seated properly Hand tighten the lid securely Replace the mixing chamber into its original position Replace the block holding the chamber tightening the black...

Page 24: ...prior to each use to ensure that the handpiece and nozzles do not become a source for cross contamination of disease or infection Prior to sterilizing the SuperSonic Turbo SST Handpiece Assembly shoul...

Page 25: ...at only GammaPure treated powder be used with the Mach 5 0 and Mach 5 0 PLUS air abrasion systems Additional GammaPure powder can be ordered from your Welch Allyn Kreativ sales representative Refer to...

Page 26: ...ions Exhaust bottle The exhaust bottle should be emptied daily and every time the powder chamber is filled It is important to make sure the internal filter is clean and tight If the filter is not tigh...

Page 27: ...Oil overflow bottle Mach 5 0 PLUS only Locate the clear oil overflow bottle at the bottom shelf of the Mach 5 0 PLUS unit Inspect the level of oil and empty as necessary Excess oil should be disposed...

Page 28: ...installed from shipping Reduce the setting or increase the supply or wait for additional supply capacity Install handpiece Install the nozzle on the handpiece Remove the plug and install the pre filte...

Page 29: ...tic powder flow Powder caking in chamber Chamber empty Nozzle partially clogged Vibrator inoperative Moisture in air line Blown pinch tube Replace powder Check powder level Check nozzle Call local ser...

Page 30: ...2V status error condition E04 EEPROM memory status error condition E05 Zero crossing sensor if idle or if not 50 Hz or 60 Hz E06 Control panel communications port error E07 Pressure switch should be o...

Page 31: ...m ID Brown 0 032 inch 0 81 mm ID Black SuperSonic Turbo SST Tipped Handpiece Assemblies This patented nozzle design is for rapid cutting and amalgam removal They are offered with the same 90 67 or 45...

Page 32: ...zle Assy 170012 3 018 66mm 90 Brown Nozzle Assy 170013 1 026 66mm 45 Black Nozzle Assy 170013 2 018 66mm 67 5 Black Nozzle Assy 170013 3 018 66mm 90 Black Nozzle Assy 170053 018 46mm 45 Supersonic Han...

Page 33: ...k Cartmount K01 00291 2 50 Micron Powder K99 00003 2 27 5 Micron Powder Brown recommended 140000 34 Micron White Powder 2 2 Pkg 140001 27 Micron White Powder 2 2 Pkg Kreativ also offers a complete lin...

Page 34: ...plastic Accessories All spare parts should be recycled according to the instructions above Products which have been in contact with the patient need to be cleaned as described in the Owner s manual P...

Page 35: ...Page 35 990008 Rev H THERE ARE NO HAZARDOUS MATERIALS PRESENT...

Page 36: ...ments are subject to Kreativ Inc approval Limited Warranty Kreativ Inc warrants the equipment to be free from defects in material and workmanship for a period of 12 months from the date of shipment Da...

Page 37: ...nditions The area it is to be stored in should meet the Environmental Limitations Transport and Storage Requirements indicated the Specifications section of Chapter 1 The unit has been designed for sh...

Reviews: