Merrychef eikon
®
e2s service and repair manual
45
_______________________________________________________________________________________________________________________________
_______________________________________________________________________________________________________________________________
5 Service information
Back to contents >
5.2
Errors and diagnostics
Error messages
Copying error messages
1.
A description of the type of error is shown. Check for a number following
‘ERROR:’ and refer to the error codes (“Fault finding” within section 5.3 of this
manual) for more details.
The serial number of the oven, model, UI (QTS) version and SRB version
information are also displayed below.
2.
Clear the error message by switching the oven Off and then back On, or by
power cycling the mains power supply to the oven.
See section 5.3 for error code list.
1.
Enter settings menu and select the USB symbol.
The USB screen appears.
2.
Open the cover of the USB
port and insert the USB
memory stick into the slot.
NOTE:
The USB memory stick may take
several seconds to load before
the screen will respond.
3.
Select ‘Upload To
USB’ on the USB
screen.
4.
Select ‘Error log to USB’
on the following screen
change pic to show correct
labels.
5.
Select the green check mark
to copy the error log to the USB
memory stick.
The update (copy download)
progress is shown followed by
the completion screen “update
status OK”.
6.
Select backspace 3 times when complete to return to
the main menu.