PF50 CE SERIES PORTABLE FILTRATION SYSTEMS
CHAPTER 6: TROUBLESHOOTING/SERVICE PROCEDURES
6-10
6.4.3.3 Replace Wand Hose
1.
Disconnect power cord from power supply.
2.
Remove cord-holder bracket and outer panels
(see Step 3, Section 6.4.2 for reference).
3.
Unscrew the hose fitting with an open-end
wrench from the elbow on the pump.
4.
Install the new hose, using care not to cross-
thread the connections. Use an approved pipe
sealant on the threads to ensure a leak-proof
connection. DO NOT OVER-TIGHTEN
THE CONNECTION.
5.
Replace the outer panels and the cord-holder
bracket.
Remove cord-holder bracket and outer panels.
Remove hose fitting (arrow) with an open-end
wrench. Use pipe sealant when installing new
hose.