PF50 CE SERIES PORTABLE FILTRATION SYSTEMS
CHAPTER 6: TROUBLESHOOTING/SERVICE PROCEDURES
6-8
6.4.3.1 Replace Motor
4.
Remove four bolts securing the pump to the
motor. Leave the plumbing connected to the
pump. Use care not to damage the flex
supply lines connected to the pump. Remove
the pump gasket for reassembly.
5.
Remove six screws securing the motor
bracket from the bottom of the base. Support
the motor with one hand when removing the
screws. Pull the motor/motor-bracket out of
the cabinet and set on floor. Use care not to
damage the motor wiring. Remove four bolts
securing the motor to the motor-bracket.
Place the replacement motor next to the old
motor for ease of rewiring.
6.
Remove the cover plate to access the motor
wiring. Splices or bombtails are needed for
two connections. Rewire the replacement
motor using the wiring diagram in Section
6.3.4.
7.
Complete installation of replacement motor
by reversing the above steps.
.
Remove six screws from the base bottom to remove
the motor and motor bracket. Remove four bolts
securing the motor to motor-bracket after removing
the bracket from the base.
Two connections require splices or bobtails
(arrows).