17
FIELD CONVERSION
INSTRUCTIONS
Natural Gas to
Propane Gas
NOTE:
Use thread sealant compatible with
propane gas on all threaded piping connections.
1.
Shut off main gas supply and disconnect
kettle from supply line.
2.
Remove GAS SHUT-OFF VALVE from kettle
supply pipe and install REGULATOR (pre-set
to 10 " W.C. pressure) supplied in field
conversion kit.
3.
Re-install SHUT-OFF VALVE using PIPE
NIPPLE supplied in kit.
4.
Remove side cover from control console.
5.
Remove PRESSURE REGULATOR UNIT from
GAS COMBINATION VALVE inside console,
and replace with blocked PRESSURE
REGULATOR UNIT from kit. Make sure
GASKET is correctly seated in recess in GAS
COMBINATION VALVE during installation.
6.
Tilt kettle. Remove kettle side box cover.
Remove screw securing end of BURNER.
Remove BURNER. Support MAIN ORIFICE
FITTING and remove MAIN ORIFICE. Install
new orifice from kit.
7.
Replace BURNER. Check ORIFICE/BURNER
alignment insuring ORIFICE points straight
into the center of the BURNER.
8.
Reconnect to gas supply. Turn on propane
gas. Tilt kettle to upright position, turn on
power and check all gas connections for leaks.
9.
Turn off power and main gas supply, and
replace all covers. Attach GAS
IDENTIFICATION STICKER to nameplate.
Field Conversion Kit
PART NO.
DESCRIPTION
SE50438
Field Conversion Kit, 6 gallon
SE50438-1
Field Conversion Kit, 12 gallon
KE53406-2
Main Orifice, 6 gallon
KE53406-12
Main Orifice, 12 gallon
KE54618
Regulator
FI00607
Pipe Nipple
KE53515-2
Pressure Regulator Unit & Gasket
NOTE:
Place GAS IDENTIFICATION STICKER on
face of GAS COMBINATION VALVE.
GAS
SHUT-OFF
VALVE
REGULATOR
PIPE
NIPPLE
PRESSURE
REGULATOR
UNIT
GAS
COMBINATION
VALVE
GASKET
TH
IS C
ON
TR
OL
HA
S B
EE
N
CO
NV
ER
TED
TO
LP
GAS
IDENTIFICATION
STICKER
BURNER
MAIN
ORIFICE
MAIN
ORIFICE
FITTING
TO MAIN GAS
SUPPLY
SE90027 Rev. 0