![Welbilt Cleveland 24CGP10 Operation Installation Maintenance Manual Download Page 37](http://html1.mh-extra.com/html/welbilt/cleveland-24cgp10/cleveland-24cgp10_operation-installation-maintenance-manual_953715037.webp)
31
2.
SteamCraft Power 10 Descaling Procedure Using the Descaling Pump System
•
Cleveland Range recommends that your service agency descales your 24CGP10.
•
If you have trained and skilled in-house maintenance personnel, you may wish to discuss
purchasing Descaling Pump System P/N: 107142 for use with Dissolve® Descaler Solution
P/N 106174 with your sales representative or service agency.
•
Use no other system of descaling.
F. Yearly Maintenance
1.
Clean the Water Line Strainer
•
Clean the water line strainer at least once a year.
•
When first installed, check the strainer more frequently to
find out how often it must be cleaned.
a.
Close the valve(s) in the water supply line(s).
b.
Unscrew the filter cap from the bottom of the strainer.
c.
Remove the filter screen and wash it with clean water.
d.
Check the O-ring for wear and replace if necessary.
e.
Put the screen back in the cap
f.
Put the cap back in the strainer.
g.
Open the water supply valve(s) and check for water leaks.
Figure 6-1
Water Line Strainer
Actual sizes and proportions
may vary.