DO NOT TRY TO LIGHT BURNERS WITH A FLAME.
This appliance
has an electronic ignition system, which automatically lights burners, senses flame,
and controls gas flow.
Burners cannot be lit with a flame.
DEATH, INJURY, OR EQUIPMENT DAMAGE may result from trying to light burners with a flame.
Without power, there is NO safe method of operation of this appliance.
DO NOT ATTEMPT TO START OR OPERATE this appliance during a power failure.
DEATH, INJURY, AND/OR EQUIPMENT DAMAGE may result.
BURN and SCALD HAZARD
Exposure to steam, condensate, and hot surfaces can cause death, burns, and scalds.
To help avoid injury:
•
Do NOT breathe steam or condensate.
•
Stand on the hinge side and away from the appliance and slowly open the cooking compartment door.
•
Open the door slightly to allow steam, condensate, and heat to vent before looking or reaching into the
cooking compartment.
•
Always wear DRY heatproof gloves when reaching into the cooking compartment or handling hot items.
Wet or damp gloves conduct heat and may cause burns when handling hot items.
Failure to follow these precautions can result in death, burns, and scalds.
CHAPTER 8 STARTUP PROCEDURE
Problems? See the Installer’s Troubleshooting Guide at the end of this manual.
Burner Ignition Test (Lighting and Shutdown Instructions)
NOTE: Perform this test before Startup Test Procedure
NOTE:
For new installations, or when air in gas lines is suspected, it may be necessary to bleed the air
from the gas lines. Bleed air as close as possible to the inlet of the automatic gas valve.
A. Lighting Instructions
(Test of function of pilot light and burner ignition system.)
1. If not already done:
a. Test the water supply lines.
b. Leak test the gas supply lines.
c. Check that the ON/OFF valve of automatic gas control valve is in the ON position.
d. Open the Main Manual Gas Valve.
2. Turn the Main External Power Switch OFF.
3. Control Panel Settings:
a. MANUAL/TIMED Switch: TIMED. (If dial timer model.)