Connection diagram with water treatment
Connection diagram
Connections on the appliance
V
United Kingdom:
DCV
Item
Name
Explanation
A
Water connection for boiler and water in-
jection
For water quality see 'Water quality' on page 97
B
Water connection for cleaning system
and recoil hand shower
For water quality see 'Water quality' on page 97
Z
Customer water pipe
Water quality: Drinking water
X
0.08 mm sediment filter
A 0.08 mm sediment filter must be installed if the water has a high
level of impurity.
W
Water treatment for softening the water to
the required soft water quality
Recommendation: Partial demineralization cartridge
Y
Shut-off device
Water tap
V
Suitable backflow preventer
(only required for steam injectors where
there is an NSF requirement, otherwise
optional)
The appliance must be installed with suitable backflow protection to
comply with applicable federal, state, and local codes.
DCV
Double check valve
The regulations for sanitary installations in Great Britain require this
component to be fitted before any installed filtration or treatment devi-
ces.
6 Installation
Installation manual
60