4.7  Auto power off  

Sets the time before meter switches off automatically if no buttons 
are pressed. The lower the value the longer your batteries may last, 
but 

remember

 all test data is lost when the meter switches off. 

Use the 

DOWN

 or 

UP

 key to modify the value, then press 

ENTER

 to 

store and return to the hardware setup menu. 
To exit without any modification, press the 

CLEAR

 key. 

 

 
 
 
 
 

4.8  Set user name 

Allows the user to change the personalized string on the wake-up 
screen. 
Use the 

DOWN

 or 

UP

 key to scroll between characters available for 

the string. Press 

ENTER

 to move onto the next character. To store 

the modified string when finished hold down the ENTER key. 
To exit without any modification, press the 

CLEAR

 key. 

 
 
 
 
 
 

4.9  Calibration 

This option is used to calibrate the roller bed.  
If the calibration jig is plugged in and bolted down (if required) press 
the 

ENTER 

key. 

 
 
 
 
 

If the roller bed cannot be found 

error 1

 will appear.  

If the roller bed cannot see that the calibration jig is plugged in,  

error

 

6

 will appear. 

For information on errors go to 

chapter 5

 
The roller bed is now ready to be calibrated. Slowly spin the roller 
bed up to speed, 

15km/h MAX

.

 

 
 
 
 
 

      - AUTO POWER OFF - 
  
                20 minutes 
 

  

        - SET USER NAME - 
  
                 welcome 
 

  

ENSURE CALIBRATION 

UNIT IS BOLTED DOWN AND 

PLUGGED IN! 

-  ENTER TO START  - 

  

-  CALIBRATION  - 

 
        SPEED:        0.0 km/h 
  DISTANCE:        0.0 m 
 

  

Summary of Contents for TAXI-CHECK

Page 1: ...TAXI CHECK Taxi Fare Meter Test System V1 3 USER MANUAL...

Page 2: ...est 3 2 Quick meter test 3 3 Start time test 3 4 Setup f f tariffs 3 5 Hardware setup 3 6 View test data Chapter 4 Hardware setup menu options 4 1 Set rf channel 4 2 Set rf power 4 3 Contrast adjust 4...

Page 3: ...Error 2 5 3 Error 3 5 4 Error 4 5 5 Error 5 5 6 Error 6 5 7 Error 7 5 8 Error 8 5 9 Error 9 5 10 Error 10 5 11 Error 11 5 12 Error 12 Chapter 6 Specifications 6 1 Handheld meter unit 6 2 Roller bed un...

Page 4: ...User manual TAXI CHECK V1 3 4 1 0 Introduction to TAXI CHECK...

Page 5: ...ress momentarily whilst in menu to scroll upwards Press momentarily to decrements value when in set up screens Hold down for 2sec for repetitive decrementing DOWN Press momentarily whilst in menu to s...

Page 6: ...n back to the main menu press the CLEAR key Step 1 1 Use the DOWN or UP key to rotate to the desired preset Press ENTER to select and proceed to step 2 To return to step 1 press the CLEAR key Step 1 2...

Page 7: ...ore the final value press ENTER and proceed to step 3 To return to step 2 press the CLEAR key Step 3 Using the DOWN or UP key increase or decrease the increment rate then press ENTER to continue to st...

Page 8: ...ENTER key Throughout different stages of the test the user may be asked to reduce the vehicles speed These speed guidelines should be followed or the test may be automatically terminated The test can...

Page 9: ...start a distance measurement test without having to enter any pre test values Only the distance traveled is stored in the results field meters over under or pass fail cannot be calculated At the main...

Page 10: ...lect the desired option and press ENTER If you want to restart that test without saving the results then select option 2 restart test this will return the user to step 1 Otherwise select option 1 stor...

Page 11: ...ect option 2 restart test this will return the user to step 1 Otherwise select option 1 store results to save test data and advance to step 3 Step 3 Since the system only has the ability to save tests...

Page 12: ...r the DOWN or UP key accordingly When the desired value is met press the ENTER key and proceed to step 3 To exit without modifying and values press CLEAR to return to step 1 Step 3 The cursor will now...

Page 13: ...n will appear Press CLEAR or ENTER to exit Step 1 All tests stored from the last test set can be viewed from this screen Use the DOWN or UP key to scroll to the desired test and press the ENTER key Pr...

Page 14: ...ore and return to the hardware setup menu To exit without any modification press the CLEAR key Warning The set channel on the meter must always match the set channel on the roller bed electronics to o...

Page 15: ...this option the hour s value will be highlighted by the flashing cursor this is the value that will be modified first Use the DOWN or UP key accordingly to modify the hours When the desired value is m...

Page 16: ...the string Press ENTER to move onto the next character To store the modified string when finished hold down the ENTER key To exit without any modification press the CLEAR key 4 9 Calibration This opt...

Page 17: ...ications When this option is entered the handheld meter will automatically poll the roller bed for the specs The screen below will appear briefly while the data is being downloaded If the roller bed c...

Page 18: ...or quick meter test The likely causes are power failure to the base unit or external rf interference The handheld meter will advance to error 1 and start searching for the unit 1 Try repeating the ca...

Page 19: ...not slow down during Error 6 the following message will appear This is the last warning given to the user before the test will abort 5 8 Error 8 The roller bed unit has failed to detect the calibrati...

Page 20: ...that the rotary encoder is secured properly on the calibration jig 2 Ensure the coupling between the encoder and the calibration wheel is tight 3 Check the calibration jig is plugged in properly 4 Che...

Page 21: ...e rate required by the NiMh batteries for 14 hours On completion the unit continues to trickle charge This ensures the batteries remain fully charged if left on charge when not in use It is recommende...

Page 22: ...t is treated with care and is used in accordance with the instructions provided This unit has no user serviceable parts and should not be dismantled In the event that your Taxi Check system requires s...

Reviews: