WEISS
Linear motor shafts HL50 - HL100 R07-2011
39/48
Maintenance
9.4 Maintenance
9
9.4
Maintenance
9.4.1
Grease the machine
The lubrication must be carried out after a service performance of
600 km, at the latest however, once a year. The respective service performance can
be seen via the WAS software in the menu Extras/Parameters. There is also the al-
ternative (as described in the documentation WAS.handling Windows programme)
of reading out and resetting the value via different interfaces.
1. Place a hand-held grease gun on each existing tapered lubrication nipple and insert
the required amount of grease.
`
Während des Schmiervorgangs das Sekundärteil von Hand etwa 40 mm bewe-
gen.
`
The pump stroke for the hand-held grease gun from Weiss is approx. 0.8 cm
3
.
2. Wipe off leaked excess grease with a soft cloth.
For further information on the hand-held grease gun from Weiss see the operating
manual for the hand-held grease gun (Art.-No. LUBEMAN-0800-00-0).
9.4.1.1 Grease
a) First lubricating by the factory and re-lubricating with LE special grease Synth EP2
with qualities as follows:
•
Standard for cleanness by FDA guideline 21 CFR 178.3570
•
Clearance by NSF H1 (National Sanitary Foundation)
Alternative the use of a comparable grease is possible.
b) Use of grease without FDA-Certifikation
•
DIN 51502: KP2K-30
•
ISO 6743-9: ISO-L-X-CCEB 2
In this case the original grease has to be pressed out of the bea-
rings completely. Do not mix greases.
9.4.1.2 Amount of grease
•
1,0 cm
3
per lubricating nipple
Type of thickener
Al-Complex
Operating temperatur for long-term lubrication
-45 °C bis +160 °C
Short time admissible temperature peak value
+200 °C
Drop point (ASTM D 2265)
> 250 °C
Worked penetration (ASTM D 217)
265 - 295
Type od base oil
synthetic
Base oil viscosity at 40 °C (ASTM D 445)
350 mm
2
/s
Water resistance (DIN 51807 T1)
0 - 90
SKF Emcor Test (DIN 51802)
Corrosion degree 0/0
Designation (DIN 51502)
KPFHC 2 P-40