6.7.5 Heat pump
6.7.5.1 Service
Heat pump
Service
The menu is only displayed in the Expert level.
Parameters
Setting
Automatic venting
Program for filling and venting the heating side.
During the automatic venting, the three way valve switches back and forth between
heating mode and DHW loading.
The pump changes the load several times in each setting.
Automatic venting takes approx. 1 hour, but can be cancelled manually using the
setting
Off
.
ManualOperation
Off
:
Manual operation deactivated.
20 … 45°C
:
Fixed value for flow setpoint temperature.
Manual defrost
Off
:
Manual defrost deactivated.
Execute
:
Starts the defrost function, the heat exchanger in the outdoor unit is being de-iced.