Installation and operating instruction
Hydraulic unit WWP LS 8 ... 16-B
9 Servicing
83306902 2/2017-05 La
73-88
9.3 Removing and refitting expansion vessel
Observe notes on servicing [ch. 9.1].
Removing
Close flow and return shut off devices of heating circuit.
Close flow and return shut off devices of hot water circuit.
Drain hydraulic unit using the outlet tap.
Hydraulic unit is depressurised.
Remove operating unit:
Open cover
2
.
Remove splash guard
5
.
Unplug electrical connections.
Open upper cover on slot
3
and remove.
Open lower cover on slot
4
and remove.
Remove screws and remove operating unit
1
.
3
4
1
5
2