65
A
10 Service
10
A
10.1 Safety notes on servicing
Service only qualified personnel!
Failure to carry out maintenance and service
work properly can have severe consequences
including serious injury or the loss of life.
Pay close attention to the following safety
notes.
Some parts of the appliance (e.g. burner
surface) become hot during operation and
could cause burns if touched. The appliance
should be allowed to cool prior to service work
being carried out.
Qualified personnel
Only qualified and experienced personnel must carry out
maintenance and service work.
Prior to all maintance and service work:
1. Switch off mains switch and appliacnce switch and
protect from reactivation.
2. Close gas isolating valve.
3. Observe installation and operating instructions.
After all maintenance and service work:
1. Function test.
2. Check flue gas losses as well as O
2
/CO values.
3. Carry out gas soundenss test.
4. Complete a test sheet.
5. Complete an inspection card.
☞
Variable rating setting in chimney sweep mode
(
➩
Ch. 5.5.2)
☞
To leave chimney sweep mode turn dial knob until
ESC appears, then press key.
Service interval
The operator should ensure that the combustion appliance
is inspected or serviced at least
– once a year –
by an agent of the manufacturer or other suitably qualified
person.
Set service interval
The time between services can be set in the heating
engineer level parameter P70 (
➩
Ch. 6.3.3). Once the time
set has elapsed, the display of the WTC displays a flashing
spanner. If a WCM-FS (accessory) is fitted, the display
shows the text Service. The service can be reset in the Info
mode (
➩
Ch. 6.3.2).
Shutdown periods
If the appliance is not used for long periods of time, the
following measures should be carried out:
1. Close gas isolating valve.
2. Switch off mains and appliance switch.
3. Empty heating system or prepare with frost protection.
4. Empty supply line to the expansion tank inside the
appliance.
5. Empty DHW heater, turn off the water.
6. Open shut off and regulating valves.
7. Switch off pumps and control circuits.
ATTENTION