By turning the dial knob, the parameter list can be
reviewed and changed if required.
If a parameter value is to be changed, press the key.
The P symbol and the value of the parameter flash. To exit
without changing the parameter value press key again,
to change the value, turn the dial knob. To save and exit
press key.
Exit parameter mode by turning the dial knob until ESC is
displayed. Then press key.
The setting parameters can be found in the following table.
The table also shows the factory settings in column
WTC 15/25.
43
6
Display Phase description
1
1
Standby control fan
2
2
Prepurge speed achieved
Tv...0
3
Countdown of prepurge in secs.
4
4
Ignition speed achieved
0...Tz
5
Flame formation time in 0.1 x secs.
6
6
Burner in operation, control active
7
7
Gas valve control V1
8
8
Gas valve control V2
9
9
Post-purge speed achieved and
post-purge
0
0
Burner off
Note:
Exiting the Info level:
Turn dial knob until ESC is displayed and confirm with
key.
6.3.3 Parameter mode
Table of operating phases
Change value