![Weir Esco ULTRAEDGE Maintenance Manual Download Page 8](http://html.mh-extra.com/html/weir/esco-ultraedge/esco-ultraedge_maintenance-manual_953268008.webp)
8
Figure 1.8.1 – Hex Bit inserted into nut
Figure 1.8.3 – 1/8
th
turn to relax bolt
Figure 1.8.4 – Bolt placement
1. With the bolt only hand tight, insert 19 mm Hex Bit
into the nut from the bottom of the shroud.
See
Figure 1.8.1.
2. Rotate the nut with the Hex Bit and breaker bar from the bottom of the shroud clockwise when looking down
on the shroud to pull the shroud back firmly to the lip. See
Figure 1.8.2.
3. Relax the nut approximately 1/8
th
turn to eliminate any binding or loading of the bolt on the lip hole.
See
Figure 1.8.3.
4. Hold Hex Bit firmly to eliminate motion of the nut and
tighten bolt until it is firmly seated. See
Figure 1.8.4.
Figure 1.8.2 – Hex Bit rotation
1.8 Supplemental Steps
If using an impact wrench to perform the installation or if you encounter conditions where the bolts are not easily
threaded you can follow these additional steps.