4.0 Dimensions of MT-8104iH 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

DIP SW & Reset button 

Com1 RS485

Com3 RS485

Com3 RS232 

b Fuse 

h  Com1 RS232

Com2 RS232 

Power connector 

Ethernet port 

VESA 75mm screw holes 

USB Host port 

Line out 

USB Client port 

f SD 

CARD 

SLOT 

   

 

GME8104H0_MT8104iH_Installation_120409 

R2mm [R0.08"]

MT8104iH

259mm [10.20"] W x 201mm [7.91"] H

259mm [10.20"]

201mm [7.91"]

286.2mm [11.27"]

212.8mm [8.38"]

SD

COM1 [RS232]
COM2 [RS232]

COM3 [RS485]
COM3 [RS232]

COM1 [RS485 2/4W]

RESET

FUSE

GND

+2

4V

DIP SW

FUSE5X20

257mm [10.12"]

199mm [7.83"]

50m

m

 [

1.

97"]

d

e

j

i

h

g

f

k

a

c

b

                         www.ipc2u.ru

Summary of Contents for MT-600 Series

Page 1: ...s not guarantee noise immunity in severe cases Proper wire routing and grounding will insure proper operation Mechanical Environment Avoid installing units in environments where severe mechanical vibration or shocks are present 2 0 Installation Instructions 2 1 Mounting Instructions 2 1 1 Location Considerations Care should be taken when locating equipment behind the unit to ensure that AC power w...

Page 2: ...tions Make sure that all local and national electrical standards are met when installing the unit Contact your local authorities to determine which codes apply 2 2 1 Power Requirements Power The MT 600 8000 can be powered by DC power only The specified voltage range is 24 20 Volts DC This insures compatibility with most controller DC systems The power conditioning circuitry inside the unit is acco...

Page 3: ...guidelines Hardware Considerations WARNING The system designer should be aware that devices in Controller systems could fail and thereby create an unsafe condition Furthermore electrical interference in an operator interface such as an MT 600 8000 can lead to equipment start up which could result in property damage and or physical injury to the equipment operator If you or your company use any pro...

Page 4: ...B D COM1 RS 232 and COM2 RS 232 Port Pin Designations COM1 RS 232 COM2 RS 232 Pin Symbol COM1 RS232 COM2 RS232 1 Not used 2 RxD Received Data 3 TxD Transmitted Data 4 TxD Transmitted Data 5 GND Signal Ground 6 RxD Received Data 7 RTS Ready to send output 8 CTS Clear to send input 9 Not used 2 3 2 Connector COM1 RS485 COM3 RS485 and COM3 RS232 The 9 Pin Female SUB D COM1 RS 485 COM3 RS 485 and COM3...

Page 5: ...ble mini side plug to HMI and another side plug into PC The PC will display Found New Hardware Wizard dialog Select Install from a list or specific location Advanced 2 Check Include this location in the search and assign the path to install Weintek HMI i Series driver from C EB8000 usbdriver 3 If the USB driver successfully be installed user can check it at Computer Management Device Manager Then ...

Page 6: ... input YES Then click OK The default password is 111111 However other passwords including download upload password and History backup password have to be reset Note When the reset action is taken projects and saved data in the HMI will all be cleared 2 4 Requirements EU directives that apply to the MT 600 8000 Series z EMC Directive 2004 108 EC electromagnetic emissions and immunity z UL508 ISBN 0...

Page 7: ...ve type Touch Accuracy Active Area Length X 2 Width Y 2 I O port COM1 RS 232 RS 485 2W 4W COM2 RS232 COM3 RS 232 RS 485 2W Ethernet port 10 100 Base T Audio YES USB Port 1 USB Host port 1 USB Client port Processor 32bit RISC 400MHz Storage 128MB flash memory DRAM 64MB DDR2 RAM on board SD card slot Support SD SDHC RTC Built in CR2032 3V lithium battery General Specification Input Power 24 20 VDC P...

Page 8: ... holes j USB Host port e Line out k USB Client port f SD CARD SLOT GME8104H0_MT8104iH_Installation_120409 R2mm R0 08 MT8104iH 259mm 10 20 W x 201mm 7 91 H 259mm 10 20 201mm 7 91 286 2mm 11 27 212 8mm 8 38 SD COM1 RS232 COM2 RS232 COM3 RS485 COM3 RS232 COM1 RS485 2 4W RESET FUSE GND 24V DIP SW FUSE5X20 257mm 10 12 199mm 7 83 50mm 1 97 d e j i h g f k a c b www ipc2u ru ...

Reviews: