•  Do not try to light any appliance.
•  Do not touch any electric switch; do not use any phone in 

your building.

•  Immediately call your gas supplier from a neighbor’s phone. 

Follow the gas supplier’s instructions.

•  If you cannot reach your gas supplier, call the fire 

department.

A.  This appliance is equipped with an ignition device 

which automatically lights the pilot. 

Do not

 try 

to light the pilot by hand.

B. 

BEFORE OPERATING

, smell all around the 

appliance area for gas. Be sure to smell next to the 

floor because some gas is heavier than air and will 

settle on the floor. See below.

C.  Use only your hand to turn the gas control knob. Never use tools. If 

the knob will not turn by hand, don’t try to repair it, call a qualified 

service technician. Force or attempted repair may result in a fire or 

explosion.

D.  Do not use this appliance if any part has been under water. 

 

Immediately call a qualified service technician to inspect the appliance 

and to replace any part of the control system and any gas control, 

which has been under water.

1. 

STOP!

  Read the safety information above on this label.

2.  Set the thermostat to lowest setting.
3.  Turn off all electrical power to the appliance.
4.  Remove from panel.

5.  This appliance is equipped with an ignition device which 

automatically lights the pilot. 

Do not

 try to light the pilot 

by hand.

6.  Turn gas control knob clockwise 

 to 

“OFF”

.

1.  Set the thermostat to lowest setting.
2.  Turn off all electric power to the appliance if service is to 

be performed.

3.  Remove front panel.
4.  Turn gas control knob clockwise 

 to 

“OFF”

. Do not force.

5.  Replace front panel.

7.  Wait five (5) minutes to clear out any gas. Then smell for 

gas, including near the floor. If you smell gas, 

STOP!

 Follow 

“B”

 in the safety information above. If you don’t smell gas, 

go to the next step.

8.  Turn gas control knob counterclockwise 

 to 

“ON”

.

9.  Turn on all electric power to the appliance.

10.  Set thermostat to desired setting.

11. If the appliance will not operate, follow the instructions 

To Turn  Off  Gas To The  Appliance

 and call your service 

technician or gas supplier.

12.  Replace front panel.

Operating instructions

•  

Spark-ignited pilot

•  

Gas valve 

— 

Honeywell VR8204/VR8304

CGa, EG-30 to EG-75,

PEG-30 to PEG-55, 

550-223-041(0906)

FOR YOUR SAFETY READ BEFORE OPERATING

OPERATING INSTRUCTIONS

 

If you do not follow these instructions exactly, a fire or explosion may result 

causing property damage, personal injury or loss of life.

WHAT TO DO IF YOU SMELL GAS

TO TURN  OFF  GAS TO THE  APPLIANCE

Summary of Contents for PEG 5 Series

Page 1: ...fire department Installation and service must be performed by a qualified installer service technician or the gas supplier If the information in this manual is not followed exactly a fire or explosion...

Page 2: ...sonal injury death or substantial property damage Indicates presence of hazards that can cause severe personal injury death or substantial property damage Indicates presence of hazards that will or ca...

Page 3: ...ler or piping must be repaired at once to prevent makeup water Do not add cold water to hot boiler Thermal shock can cause sections to crack Boiler operation Do not block flow of combustion or ventila...

Page 4: ...fold orifices 5 Control module 6 Inducer CGi only 7 Vent damper CGa only 8 Water temperature sensor 9 Transformer 10 Spill switch CGa only 11 Air pressure switch CGi only 12 Rollout thermal fuse eleme...

Page 5: ...burner 3 Main burner 4 Gas manifold orifices 5 Control module 7 Vent damper 9 Transformer 10 Spill switch 12 Rollout thermal fuse element 13 Low water cutoff steam boilers 14 Limit control s 15 Draft...

Page 6: ...only by a qualified service technician Owner maintenance see following pages for instructions A nnual start up Inspect Reported problems Boiler area Air openings Flue gas vent system Pilot and main b...

Page 7: ...echnician to inspect the boiler and vent system for possible damage from acid corrosion If products cannot be removed immediately call a qualified service technician to install an outside combustion a...

Page 8: ...ators relief valve and other fittings Immediately call a qualified service technician to repair any leaks 1 Visually inspect all parts or the flue gas venting system for any signs of blockage leakage...

Page 9: ...ot flame sensor spark ignited pilot 3 Thermocouple or thermopile or pilot flame sensor glowing cherry red Improper pilot flame 1 Overfired Large flame lifting or blowing past pilot flame sensor 2 Unde...

Page 10: ...turn thermostat to normal setting Test low water cutoff all steam boilers water boilers if installed If the system is equipped with a low water cutoff test the low water cutoff periodically during the...

Page 11: ...to clean the valve seat If the valve continues to weep afterwards contact your qualified service technician to inspect the valve and system 5 If water does not flow from the valve when you lift the le...

Page 12: ...tempt to light the pilot Use caution when attempting to light the propane pilot This should be done by a qualified service technician particularly if pilot outages are common Periodically check the od...

Page 13: ...tat to lowest setting 3 Turn off all electrical power to the appliance 4 Remove from panel 5 This appliance is equipped with an ignition device which automatically lights the pilot Do not try to light...

Page 14: ...at to lowest setting 3 Turn off all electrical power to the appliance 4 Remove front panel 5 This appliance is equipped with an ignition device which automatically lights the pilot Do not try to light...

Page 15: ...wer to the appliance 4 Remove front panel 5 This appliance is equipped with an ignition device which automatically lights the pilot Do not try to light the pilot by hand 6 Depress gas control knob sli...

Page 16: ...CGa CGi EG EGH LGB PEG Boilers 16 Part Number 550 142 801 1112 Operating instructions Spark ignited pilot Gas valve Robertshaw 7200 CGa 25 to CGa 6 EG 30 to EG 50 PEG 30 to PEG 50...

Page 17: ...User s Information Manual 17 Part Number 550 142 801 1112 Operating instructions Spark ignited pilot Gas valve Robertshaw 7000DERHC EGH 85 to EGH 125...

Page 18: ...the thermostat to lowest setting 3 Turn off all electrical power to the appliance 4 Remove jacket front panel 5 This appliance is equipped with an ignition device which automatically lights the burner...

Page 19: ...User s Information Manual 19 Part Number 550 142 801 1112 Operating instructions Spark ignited pilot LGB...

Page 20: ...se stop leak compounds Black water condition Oxygen corrosion due to leaks in boiler and piping Have qualified service technician repair at once Keep pH of water between 7 0 to 8 5 Popping or percolat...

Reviews: