Go to www.weil-mclain.com to locate Weil-McLain distributors
Part number 550-100-131/0120
– 116 –
®
gas
-
fired
water
boiler
— 220/299/300/399
Boiler Manual
Replacement parts
DO NOT SERVICE THE
BOILER WITHOUT A
Evergreen
®
MAINTENANCE
KIT AVAILABLE
The
Evergreen
®
maintenance kit includes compo-
nents that may have to be replaced when accessing or
disassembling parts of the boiler. Failure to replace
damaged components and to use only the parts spe-
cifically intended for the boiler can result in severe
personal injury, death or substantial property damage.
See Figure 111, page 117 for part number.
Failure to adhere to these guidelines can
result in severe personal injury, death or
substantial property damage.
OBTAIN PARTS ONLY THROUGH
WEIL-McLAIN
Replacement parts must be purchased through a local
Weil-McLain distributor. When ordering, specify boiler model
and size and include description and part number of replace-
ment part. Results from using modified or other manufactured
parts will not be covered by warranty and may damage boiler
or impair operation.
THE BOILER CONTAINS CERAMIC
FIBER MATERIALS
The boiler contains ceramic fiber materials
. Use care when
handling these materials per instructions on page 94 of this
manual. Failure to comply could result in severe personal injury.
REINSTALL JACKET DOOR
Inspect boiler jacket door gaskets and reinstall boiler jacket
front door after start or servicing. The boiler door must be
securely fastened to the boiler to prevent boiler from drawing
air from inside the boiler room. This is particularly important
if the boiler is located in the same room as other appliances.
Failure to keep the door securely fastened could result in severe
personal injury or death.
BEFORE SERVICING or MAKING
CONNECTIONS —
ALWAYS TURN POWER OFF TO THE BOILER TO
PREVENT ELECTRICAL SURGES, WHICH CAN DAM-
AGE BOILER COMPONENTS.
LABEL WIRES BEFORE REMOVING
Label all wires prior to disconnection when ser-
vicing controls. Wiring errors can cause improper
and dangerous operation.
Figure 110
Propane conversion kits
Boiler
model
Kit
part number
Installation
instructions
EVG 220
540-202-840
See
page 12
EVG 299/300
540-202-841
See
page 12
EVG 399
540-202-842
See
page 12
REPLACEMENT PART NUMBERS
Weil-McLain part numbers are found in this
manual and in
Weil-McLain Boilers and Con-
trols Repair Parts Lists
.
WHEN OPERATING THE BOILER
ON PROPANE GAS
ALL
Evergreen
®
boilers must be
converted in order to operate with
propane gas
.