Networking and configuring the EV charging box
92
Operating instructions – AC SMART
Setting up load/charge management
You must be logged in as an Admin. Electrician only!
The Modbus TCP interface must be configured as WiFi or Ethernet, see
Chapter 9.4. There must be a control box in each charging network. Each
additional EV charging box that is part of the same charging network must be
configured as a satellite box.
Steuerbox
Satellitenboxen
Image 9.6 Charging network
►
Click
Load Management
.
►
Activate
satellite box
or
control box
.
►
Only for the control box: Enter the desired value for the global current limit
[A].
►
Only for the control box: enter the IP addresses for all connected satellite
boxes.
►
Click
Save
.
The
Connected
field displays whether communication between the satellite
box and control box is possible.
Setting up the OCPP backend connection
You must be logged in as an Admin. Electrician only!
The data required to set up the OCPP connection is available from the
provider of your OCPP backend.
►
Click
Network/Cloud.
.
►
Enter the data.
►
Click
Save
.
Updating firmware
To update the firmware, the EV charging box must be connected to your
computer or mobile device via LAN, see Chapter 9.1
. The current firmware is
available as a download on the Weidmüller website.
►
Click
Config/General.
►
Click
Select file.
► Choose a firmware file.
►
Click
Upload.
The file is loaded to the EV charging box. This may take up to one minute.
After the upload is complete tick the box in the field
Upload Status
. The
change is adopted the next time the EV charging box is restarted.
►
Click
Restart
.
Prerequisite
Prerequisite
Prerequisite