![Weidmuller UR20-4DI-4DO-PN-FSOE Manual Download Page 47](http://html.mh-extra.com/html/weidmuller-0/ur20-4di-4do-pn-fsoe/ur20-4di-4do-pn-fsoe_manual_952407047.webp)
5 Detailed descriptions of safe modules
| Digital input module UR20-8DI-PN-FSPS, UR20-8DI-PN-FSPS-V2
47
u-remote IP20 modules for functional safety manual
1484600000/04/06.2017
5.6 Digital input module UR20-8DI-PN-FSPS, UR20-8DI-PN-FSPS-V2
Digital input module UR20-8DI-PN-FSPS (Best.-Nr. 1335070000), UR20-8DI-PN-FSPS-V2
(Best.-Nr. 2464590000)
The UR20-8DI-PN-FSPS or UR20-8DI-PN-FSPS-V2 digital in-
put module is a safe I/O module for the PROFIsafe protocol.
The module can detect up to 8 binary control signals. Two
sensors can be connected to each connector using a 2-wire,
3-wire or 4-wire connection. In the event that the available
supply current of 0.8 A per plug will not suffice, the sensor
supply must be realised using the auxiliary outputs of an-
other module (e.g. potential distribution module) within the
same power segment.
A status LED is assigned to each channel. The module elec
-
tronics supply the connected sensors with power from the
input current path (I
IN
)
A test pulse check of the inputs can be parameterised as a
cross-circuit detection between input singal and supply volt-
age, between different input signals or other signals. Thus an
input gets active only when the signal of the dedicated aux-
iliary output is pending. The test pulses must be disabled if a
safety relay with OSSD outputs generating own test pulses is
connected.
1
2
3
4
2
1
3
4
1
2
3
4
2
4
3
1
2
4
3
1
1
2
3
4
2
1
3
4
1
2
3
4
2
4
3
1
2
4
3
1
DI 0 (PN)
AUX-O 0
AUX-O 1
DI 1 (P)
DI 2 (PN)
AUX-O 2
AUX-O 3
AUX-O 0
AUX-O 1
AUX-O 2
AUX-O 3
DI 3 (P)
DI 4 (PN)
AUX-O 4
AUX-O 5
DI 5 (P)
DI 6 (PN)
AUX-O 6
AUX-O 7
DI 7 (P)
8DI·PN
DI 0 (PN)
GND
24 V DC
GND
24 V DC
DI 1 (P)
DI 2 (PN)
DI 3 (P)
DI 4 (PN)
AUX-O 4
AUX-O 5
DI 5 (P)
DI 6 (PN)
AUX-O 6
AUX-O 7
DI 7 (P)
8DI·PN
Safety relay
with OSSD
outputs
1
Safety relay
with OSSD
outputs
2
Connection diagram UR20-8DI-PN-FSPS , UR20-8DI-PN-FSPS-V2
A safety sensor that is being connected in a dual chan-
nel mode (safety architecture of category 4 acc. to
DIN EN ISO 13849) must allocate the PN and the P-input of
one connector.
Summary of Contents for UR20-4DI-4DO-PN-FSOE
Page 1: ...Remote I O system u remote IP20 modules for functional safety Manual Original Letʼs connect ...
Page 8: ...8 1484600000 04 06 2017 u remote IP20 modules for functional safety manual ...
Page 20: ...20 1484600000 04 06 2017 u remote IP20 modules for functional safety manual ...
Page 70: ...70 1484600000 04 06 2017 u remote IP20 modules for functional safety manual ...
Page 72: ...72 1484600000 04 06 2017 u remote IP20 modules for functional safety manual ...
Page 96: ...96 1484600000 04 06 2017 u remote IP20 modules for functional safety manual ...
Page 102: ...ANNEX A 6 1484600000 04 06 2017 u remote IP20 modules for functional safety manual ...
Page 103: ...ANNEX A 7 1484600000 04 06 2017 u remote IP20 modules for functional safety manual ...
Page 104: ...ANNEX A 8 1484600000 04 06 2017 u remote IP20 modules for functional safety manual ...
Page 105: ...ANNEX A 9 1484600000 04 06 2017 u remote IP20 modules for functional safety manual ...
Page 106: ...ANNEX A 10 1484600000 04 06 2017 u remote IP20 modules for functional safety manual ...
Page 107: ...ANNEX A 11 1484600000 04 06 2017 u remote IP20 modules for functional safety manual ...
Page 108: ...ANNEX A 12 1484600000 04 06 2017 u remote IP20 modules for functional safety manual ...
Page 109: ...ANNEX A 13 1484600000 04 06 2017 u remote IP20 modules for functional safety manual ...
Page 110: ...ANNEX A 14 1484600000 04 06 2017 u remote IP20 modules for functional safety manual ...
Page 111: ...ANNEX A 15 1484600000 04 06 2017 u remote IP20 modules for functional safety manual ...
Page 112: ...ANNEX A 16 1484600000 04 06 2017 u remote IP20 modules for functional safety manual ...
Page 113: ...ANNEX A 17 1484600000 04 06 2017 u remote IP20 modules for functional safety manual ...
Page 114: ...ANNEX A 18 1484600000 04 06 2017 u remote IP20 modules for functional safety manual ...
Page 115: ...ANNEX A 19 1484600000 04 06 2017 u remote IP20 modules for functional safety manual ...
Page 116: ...ANNEX A 20 1484600000 04 06 2017 u remote IP20 modules for functional safety manual ...
Page 117: ...ANNEX A 21 1484600000 04 06 2017 u remote IP20 modules for functional safety manual ...
Page 118: ...ANNEX A 22 1484600000 04 06 2017 u remote IP20 modules for functional safety manual ...
Page 119: ...ANNEX A 23 1484600000 04 06 2017 u remote IP20 modules for functional safety manual ...
Page 120: ...ANNEX A 24 1484600000 04 06 2017 u remote IP20 modules for functional safety manual ...
Page 121: ...ANNEX A 25 1484600000 04 06 2017 u remote IP20 modules for functional safety manual ...
Page 122: ...ANNEX A 26 1484600000 04 06 2017 u remote IP20 modules for functional safety manual ...
Page 124: ...A 28 1484600000 04 06 2017 u remote IP20 modules for functional safety manual ...