background image

 
 

 

Operation and Service Instructions RR/QR/Magnum 

 

 

 
File: N:\Bedienungsanleitungen aktuell\Bedienungsanleitungen_Fremdsprachlich\Englisch\Plattenständer 
Erstellt 12.09.2013  

Page  9 of 11 

 
 
 
 

6.1.1  Option Trapezoidal Supports 

 

 

Picture 6.8 Example 

Optional Trapezoidal Supports 

 

Total height [cm] 

141 cm 

Max. Bearing Capacity [kg] 

See following Table 

Total width [cm] 

50 cm 

Article Number 

8010503 

Total depth [cm] 

12 cm 

 

 

 

 

Attention! 

Values of the Table are valid only when using a Slab Height of from 1,8 m and a Slab 

width of from 2,5 m.  Load equally distributed on 2 supports!

 

 

 

Min. inclination angle 

α 

[Degree] 

70 

80 

87 

Max. total slab thickness 

[cm] 

30 

58 

190 

 

7   Maintenance and Inspection 

 
The Slab Stand requires regular Maintenance. 
 

 

Follow strictly the safety precautions 

– regulations as outlined in Chapter 4.3! 

 

 

Only those individuals with adequate knowledge and training may implement the following activities!  The 

dealer or manufacturer is not liable for any damages incurred due to non-compliance to these 

instructions!

 

 

 
According to ZH 1/428 regulations, this is a storage item, which has to be checked regularly by an expert according to need.   
 

The Inspection has to be implemented at least once a year:

 

 

 

Strict attention must be given to the safety precautions as outlined in Chapter 4.3.! 

 

Check at least yearly the Slab Stand for rust spots in particular at the welding joints! 

 

Remove the rust and protect these parts from future corrosion by means of an anti-rust lubrication e.g. zinc spray. 

  

Summary of Contents for BISON 115161

Page 1: ...ing Instructions 2 4 Regulations for use of the Slab Stands 3 4 1 Field of Application of the Slab Stands 3 4 2 Inappropriate Application 3 4 3 Safety Regulations 3 4 4 Machine Identification Plate 4 4 5 Technical and Structural Data 4 4 5 1 Slab Stand RR with Supporting Tubes 1 Meter 4 4 5 2 Slab Stand RR with Supporting Tubes 1 5 Meter 4 4 5 3 Slab Stand Bison with Supporting Tubes 1 5 Meter 4 4...

Page 2: ...8231 60 07 148 Machine Type RR QR Magnum Application The Slab Stand is a device to facilitate stocking of stone slabs Machine number Signature Herr Nagy We hereby certify that the above mentioned device corresponds to the requirements in accordance with the above guidelines 3 Explanation of the Symbols and Warning Instructions The following explanations of the warning symbols appearing on the mach...

Page 3: ...able iron tubes to use as a bearing surface for the stone slabs 4 2 Inappropriate Application The slab stands can be used only to store stone slabs upright Use the slab stand for the intended purposes and avoid using any materials which can damage the metal or other parts of the device The slab stand is complete and particularly appropriate for the indicated ranges of application Do not store any ...

Page 4: ...and RR with Supporting Tubes 1 Meter Total height cm 110 cm Max Bearing Capacity kg See Chapter 5 1 Bearing Cap Total width cm 300 cm Net weight 250 kg Total depth cm adjustable Height of Iron Tube 100 cm 4 5 2 Slab Stand RR with Supporting Tubes 1 5 Meter Total height cm 160 cm Max Bearing Capacity kg See Chapter 5 1 Bearing Cap Total width cm 300 cm Net weight 280 kg Total depth cm adjustable He...

Page 5: ... of tilting and breakage can occur caused by irregular charge Place the slab stands on a firm ground Make certain that these features are accomplished by using a spirit level or by shaking the slab stands Make certain that the ground has adequate load capacity Always adhere to the regulations for the prevention of accidents Mounting of the rails While handling the slab stand always wear the approp...

Page 6: ...s by means of a suitable lifting gear and lean the slabs carefully against the iron tubes Attention Avoid any crush or collision while loading and discharging the slabs Danger of tilting and crushing Picture 5 1 Assembled Slab Stand Type RR 6 1 Carrying Capacity of the various Slab Stands Lean the slabs against the Iron tubes as steeply as possible and avoid overcharging the iron tubes Pay attenti...

Page 7: ...nd a slab height of 2 meters Attention Stated values of the Table and Diagram are only valid with a Slab Height of from 2 meters Check to see whether all Iron tubes are fully functional and have no deformations or splits Attention Risk of tilting or crushing by faulty support tubes Attention Any modifications of the Tubes or the Rails as well as the non observance of these operating instructions i...

Page 8: ... 09 2013 Page 8 of 11 Picture 6 4 Example of too little clearance angle with too large overall thickness of the slab Picture 6 5 Example of a too little clearance angle with a too large overall thickness of the slab Picture 6 6 Overloaded iron support tubes showing risk of breakage respectively crushing Picture 6 7 Example of buckled tube due to overloading ...

Page 9: ...0 7 Maintenance and Inspection The Slab Stand requires regular Maintenance Follow strictly the safety precautions regulations as outlined in Chapter 4 3 Only those individuals with adequate knowledge and training may implement the following activities The dealer or manufacturer is not liable for any damages incurred due to non compliance to these instructions According to ZH 1 428 regulations this...

Reviews: