6  Operating Instructions for the Slab stands 

 
 

 

Load the Slab stands always starting from the middle and 
distributing the load over the whole length. 

 
 

       

 
 
 

Attention! Risk of tilting by irregular loading on the supporting 
tubes! 

 

 

Avoid loading the iron tubes only from one side! The bearing 
edges of the slab have always to be vertical with respect to 
the perforated rails! 

 

While loading avoid collisions and blows on the tubes! 
Release the slabs by means of a suitable lifting gear and 
lean the slabs carefully against the iron tubes! 

 
 

       

 
 
 

Attention! Avoid any crush or collision while loading 
and discharging the slabs!  
Danger of tilting and crushing! 

 

 

 

Picture 5.1

 

– Assembled Slab Stand Type RR 

6.1  Carrying Capacity of the various Slab Stands 

 

 

Lean the slabs against the Iron tubes as steeply as possible and avoid overcharging the iron tubes. Pay attention to the 
following drawing concerning the minimal front tilt angle according to the total slab thickness (Picture 6)!  

 

 

Attention! 

Risk of tilting and crushing by overloading the iron tube, caused by reduced 

clearance angle or larger load!   

 

 
Picture 5.2 serves to clarify the following tables and diagram as well as the utilized terminology and serves as an example!  
 
 
 
 
 

Picture 5.2

 - Minimal clearance angle by admissible load. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

 

 

 

Summary of Contents for BISON 115161

Page 1: ...ing Instructions 2 4 Regulations for use of the Slab Stands 3 4 1 Field of Application of the Slab Stands 3 4 2 Inappropriate Application 3 4 3 Safety Regulations 3 4 4 Machine Identification Plate 4 4 5 Technical and Structural Data 4 4 5 1 Slab Stand RR with Supporting Tubes 1 Meter 4 4 5 2 Slab Stand RR with Supporting Tubes 1 5 Meter 4 4 5 3 Slab Stand Bison with Supporting Tubes 1 5 Meter 4 4...

Page 2: ...8231 60 07 148 Machine Type RR QR Magnum Application The Slab Stand is a device to facilitate stocking of stone slabs Machine number Signature Herr Nagy We hereby certify that the above mentioned device corresponds to the requirements in accordance with the above guidelines 3 Explanation of the Symbols and Warning Instructions The following explanations of the warning symbols appearing on the mach...

Page 3: ...able iron tubes to use as a bearing surface for the stone slabs 4 2 Inappropriate Application The slab stands can be used only to store stone slabs upright Use the slab stand for the intended purposes and avoid using any materials which can damage the metal or other parts of the device The slab stand is complete and particularly appropriate for the indicated ranges of application Do not store any ...

Page 4: ...and RR with Supporting Tubes 1 Meter Total height cm 110 cm Max Bearing Capacity kg See Chapter 5 1 Bearing Cap Total width cm 300 cm Net weight 250 kg Total depth cm adjustable Height of Iron Tube 100 cm 4 5 2 Slab Stand RR with Supporting Tubes 1 5 Meter Total height cm 160 cm Max Bearing Capacity kg See Chapter 5 1 Bearing Cap Total width cm 300 cm Net weight 280 kg Total depth cm adjustable He...

Page 5: ... of tilting and breakage can occur caused by irregular charge Place the slab stands on a firm ground Make certain that these features are accomplished by using a spirit level or by shaking the slab stands Make certain that the ground has adequate load capacity Always adhere to the regulations for the prevention of accidents Mounting of the rails While handling the slab stand always wear the approp...

Page 6: ...s by means of a suitable lifting gear and lean the slabs carefully against the iron tubes Attention Avoid any crush or collision while loading and discharging the slabs Danger of tilting and crushing Picture 5 1 Assembled Slab Stand Type RR 6 1 Carrying Capacity of the various Slab Stands Lean the slabs against the Iron tubes as steeply as possible and avoid overcharging the iron tubes Pay attenti...

Page 7: ...nd a slab height of 2 meters Attention Stated values of the Table and Diagram are only valid with a Slab Height of from 2 meters Check to see whether all Iron tubes are fully functional and have no deformations or splits Attention Risk of tilting or crushing by faulty support tubes Attention Any modifications of the Tubes or the Rails as well as the non observance of these operating instructions i...

Page 8: ... 09 2013 Page 8 of 11 Picture 6 4 Example of too little clearance angle with too large overall thickness of the slab Picture 6 5 Example of a too little clearance angle with a too large overall thickness of the slab Picture 6 6 Overloaded iron support tubes showing risk of breakage respectively crushing Picture 6 7 Example of buckled tube due to overloading ...

Page 9: ...0 7 Maintenance and Inspection The Slab Stand requires regular Maintenance Follow strictly the safety precautions regulations as outlined in Chapter 4 3 Only those individuals with adequate knowledge and training may implement the following activities The dealer or manufacturer is not liable for any damages incurred due to non compliance to these instructions According to ZH 1 428 regulations this...

Reviews: