7�2
Installing the media hose line
Please note:
Subsequent mentions of descriptions and position numbers refer to
chapter 3. Product overview / product description on page 10
.
Î
Unscrew the protection cap from the port.
Î
When mounting the filling hose, hold an open-ended
spanner against the spanner flat A/F(1) (
Î
Screw the media inlet "B1" pressure-tight onto the connec-
tion port of the filling hose (
For the tightening torque, please refer to the table below.
Note:
For NPT thread, first wrap Teflon tape round the
tapered screw fitting (1.5 layers). Screw the fitting
finger-tight into the port and install it in accordance with
the information in the table below.
Connections
Torque
G thread
Assembly turns
NPT thread*
NPT 1/4
--
2.0 - 3.0
NPT 3/8
--
2.0 - 3.0
M16x1.5
20 Nm ± 2 Nm
--
* One turn corresponds to 360°
Î
Please note the connection size marked on your product.
- Other connection sizes are available on request.
7�3
Checking the connection for leak tightness
Î
Connect the connector to a closed cylinder valve.
Î
Slowly apply the operating pressure to the connector and media line.
Caution:
The cylinder valve must be closed/locked.
Î
Check the connector, the connection to the media line and the connection to the
cylinder valve for leak tightness.
Figure 2
A/F(1)