8�3
Disconnection
Î
After completing the filling process and thorough venting of
the media line, close the connector up again.
Caution:
First depressurize the system before releasing
the connection.
Attention:
The system must be fully depressurized so that
the safety peg (Pos. 5) on the connector can retract and
the actuation is no longer blocked (
.
Disconnecting a TW57 with bail actuation and actuation lever
Î
Fold the actuation unit (Pos. 1) upwards as far as it will go
(
. The clamping jaws open.
Note:
The safety peg (Pos. 5) at the connector must be
fully retracted. Actuating before the equipment is fully
depressurized and before the safety peg has fully
retracted can result in damage to the safety peg.
Î
Pull the connector
straight
). Doing so will
prevent any damage to the front seal caused by any sharp
edges on the cylinder valve.
Attention:
In the event that you cannot remove the
connector:
- Wait a few moments
- Never use excessive force
- Do not use any tools (e.g. hammer)
- Make sure that the connector is depressurized. The
safety peg (Pos. 5)
at the connector must be fully
retracted.
Figure 11
Figure 12
Figure 13
MD-10058-L51-R1.1.0-03