Clamp the
outlet housing (Pos. 100)
into the vice with clamping
jaws.
Screw the
inlet housing (Pos. 200)
into the
outlet housing (Pos. 100).
For this purpose, use the
torque wrench, the plug-in
adapter and the rolling fork
insertion tool A/F2-41.
Tightening torque:
60 Nm
Please note:
When reinstalling the wire filter insert into the system, please follow the
Chapter 7. Installation on page 17
.
MD-10211-L51-R1.1.0-03
Page 27
Operating instructions
AE