7�4
Installation of the CLICKMATE
®
TW154 FL with the adaptor W30124
Î
Unscrew the existing screw
filling connection from the filling bar.
Î
Premount the adaptor (Pos. 14).
Î
Put the union nut (Pos. 12) and the counter hexagon nut (Pos. 16) onto the
adaptor (Pos. 14).
Î
Lightly grease the O-ring (Pos. 15) with part no. E99-10 and then insert it into the rear
plan recess of the adaptor (Pos. 14).
Î
Screw the adaptor (Pos. 14) completely into the filling bar.
Tightening torque
20 Nm ± 2 Nm
Î
Tighten the counter hexagon nut (Pos. 16).
Î
Lightly grease the O-ring (Pos. 13) with WEH
®
Lubricant part no. E99-10 and then
insert it into the plan recess of the adaptor (Pos. 14).
Î
Screw the union nut (Pos. 12) onto the operating media inlet “B1” of the adapter.
Note:
The bail of the adapter must be aligned horizontally.
Î
Tighten the union nut (Pos. 12). While tightening, hold the wrench size A/F(1) of the
adapter.
For the tightening torque, please refer to the table below.
Connection
Torque
Union nut
20 Nm ± 2 Nm
M16x1.5 male thread
20 Nm ± 2 Nm
Î
Please note the connection size marked on your product.
- Other connection sizes are available on request.
11
13
16
12
14
15
B1
Pos�
Description
11
CLICK
MATE
®
TW154
12
Union nut
13
O-ring
14
Adaptor
15
O-ring
16
Counter hexagon nut
Definition of ports
B1
Media inlet
MD-10081-L51-R1.1.0-03