Installation of the CLICKMATE
®
TW154 on a filling hose
Please note: Subsequent mentions of descriptions and position numbers refer to
following illustrations on
Chapter 7. Installation
.
Î
Unscrew the protection cap from the port.
Î
When mounting media hose line, hold an open-ended
spanner against the spanner flat AF(1) (
Figure 1
).
Î
Screw the "B1" media inlet pressure-tight to the port for
the media hose line (
Figure 1
).
For the tightening torque, please refer to the table below.
Connection
Torque
M16x1.5 male thread
20 Nm ± 2 Nm
Î
Please note the connection size marked on your product.
- Other connection sizes are available on request.
Figure 1
A/F(1)
B1
MD-10081-L51-R1.1.0-03