Installation and Connection
CFW11W | 2-2
Table 2.2: Currents and settings at 500-690V
Rated Current (A)
Number of UP11-05
power units
ND
HD
640
477
1
1216
906
2
1824
1359
3
2432
1812
4
3040
2265
5
For other components, such as cable set and fiber optic cables, refer to item 3.2 – Component List of the
CFW11M user manual.
2.3.
MECHANICAL INSTALLATION
The power units must be installed on the drive panel appropriately, allowing easy extraction and reassembly in
case of maintenance. The fastening must be such to avoid damage during panel transportation.
Figure 2.1: UP11 hosting eyes
Figure 2.2: Mounting of the UP11 side by side without lateral gap