2.4 TILT COUPLER OPERATION
To operate the rotary action of the I-Lock Tilt Coupler a clear understanding of the way
in which the coupler has been connected to the auxiliary hydraulics of the excavator
is required.
Depending on customer preference and full function requirement of the carrier
machine the rotary actuation of the I-Lock Tilt Coupler can be operated in a number of
different ways.
In most circumstances the activation of auxiliary hydraulic circuits can be achieved by
either a foot pedal or a joystick (Fig 2.6.1 & Fig 2.6.2) configured to achieve the multi
function that the customer needs to fulfil his operation in an efficient manner.
For full instructions on how to activate the rotary action of the I-Lock Tilt™ Coupler
please refer to the install manual and consult with the qualified hydraulic installer or
dealer of the carrier machine.
2.5 TILT COUPLER PRECUATIONS
The I-Lock Tilt Coupler has been designed to withstand the normal rigors of general earthmoving and construction
operations for which the carrier machine has been designed.
Abuse of the product can cause serious damage to the working mechanism and will void warranty in all circumstances.
Maximum bucket widths recommended for use on the I-Lock Tilt Coupler must not be exceeded. See table below.
Model
Weight Class (t)
Helac Rotary Actuator
Maximum Bucket Width (mm)
CMT-037
2.9 to 3.7
PT06
1200
CMT-045
3.8 to 4.5
PT07
1400
CMT-055
4.6 to 5.5
PT07
1400
CMT-070
5.6 to 7.0
PT100
1500
CMT-099
7.1 to 9.9
PT100
1500
CMT-130
10.0 to 13.0
PT180
1800
CMT-170
14.0 to 17.0
PT180
1800
CMT-210
18.0 to 21.0
PT10
2000
SECTION 2: