Wecon VD2 SA Series Servo Drives User Manual (Full V1.0)
11
WECON technology Co., Ltd.
3.1.3 Installation environment
The installation environment of the servo drive has a direct impact on the normal function of the
drive and its service life. Therefore, the installation environment of the servo drive must meet the
following conditions:
Project
Illustrate
Ambient temperature -10
℃
~40
℃
(no freezing)
Ambient humidity
-20%~90%RH (no condensation)
Storage temperature -20
℃
~60
℃
Storage humidity
-20%~90%RH (no condensation)
Protection grade
IP65
Vibration
Less than 0.5G (4.9m/s2), 10~60Hz (non-continuous operation)
Power Systems
TN system*
✎
Note:
The neutral point of the power system is directly connected to the ground, and the
exposed metal components are connected to the ground through a protective grounding
conductor.
3.1.4 Installation matters
(1) Installation specifications
In order to achieve a good cooling cycle effect, ensure that there is enough ventilation space
around it when installing the servo drive, and be sure to comply with the installation standards in
the control cabinet shown in the figure below, otherwise it may cause the drive to malfunction. For
typical minimum installation dimensions, Please refer to Figure 3-3.
>50mm
>50mm
>20mm
>20mm
>50mm
>50mm
>20mm
>20mm
(A) Type A drive
(B) Type B drive
Figure 3-3 Minimum installation size