Wecon VD2 SA Series Servo Drives User Manual (Full V1.0)
107
WECON technology Co., Ltd
(negative logic)
4: CW/CCW (negative logic)
5: A, B phase quadrature
pulse (4 times frequency
negative logic)
P00-13
Maximu
m
position
pulse
frequenc
y
Shutdown
setting
Effective
immediately
300
1~500
Set the maximum
frequency of external pulse
instruction
KHz
P00-14
Position
pulse
anti-inter
ference
grade
Operation
setting
Power on
again
2
0~9
Set the anti-interference
grade of the external pulse
instruction.
0: no filtering;
1: Filtering time 128ns
2: Filtering time 256ns
3: Filtering time 512ns
4: Filtering time 1.024us
5: Filtering time 2.048us
6: Filtering time 4.096us
7: Filtering time 8.192us
8: Filtering time 16.384us
9: Filtering time 25.5us
-
P00-16
per
rotation
of the
motor
Number
of
instructi
on
pulses
Shutdown
setting
Effective
immediately
10000
0~131
072
Set the number of
instruction pulses per
rotation of the motor.
When the setting value is 0,
[P0-17]/[P0-19] Electronic
gear 1/2 numerator,
[P0-18]/[P0-20] Electronic
gear 1/2 denominator is
valid.
pulse
unit
P00-17
Electroni
c gear 1
numerat
or
Operation
setting
Effective
immediately
1
1~429
49672
94
Set the numerator of the
1st group of electronic gear
ratio for position
instruction frequency
division/multiplication.
[P0-16] It is effective when
the instruction pulse
number of one motor
rotation is 0.
-
P00-18
Electroni
c gear 1
denomin
ator
Operation
setting
Effective
immediately
1
1~429
49672
94
Set the denominator of the
1st group of electronic gear
ratio for position
instruction frequency
division/multiplication.
[P0-16] It is effective when
the instruction pulse
number of one motor
-