Specifications 

 
1)

 

Please refer to the LX3V user manual for the general specification of LX3V-2DAV-BD. 

2)

 

LX3V-2DAV-BD is powered supply by LX3V main unit. 

 

Table 4-1 

Specification 

Item   

Voltage output 

Input range 

DC-10V~10V (the external load resistance is no less than 2KΩ) 

Digital output   

12 bit binary 

Resolution   

5mV[10V default scope 1/2000] 

Precision   

Full scale ±1% 

A/D 

conversion 

time 

1 scan time

The analog digital conversion is completed by the 

END order

 

Characteristic 

 

Insulation   

No insulation in each PLC channel

 

Occupied points 

Zero point 

 

5.

 

Wire 

 

Warning 

Make  sure  cut  off  the  electricity  before  installation/disassembly,  to  prevent  electric  shock  or 

product damages. 

 

Caution

   

1)

 

Please keep the signal cable from the high-voltage cable at lease 100mm.

 

Summary of Contents for LX3V-2DAV-BD

Page 1: ...LX3V 2DAV BD User manual Website http www we con com cn en Technical Support support we con com cn Skype fcwkkj Phone 86 591 87868869 QQ 1043098682 Technical forum http wecon freeforums net...

Page 2: ...2 When output current make sure that the load resistance should be less than 500 otherwise the output will be lower 3 Please fixed BD module on the PLC poor contact may lead to failure 4 BD module an...

Page 3: ...V 10V 2000 2000 D8116 The digital value of channel 1 10V 10V 2000 2000 D8117 The digital value of channel 2 10V 10V 2000 2000 3 Dimension Table 3 1 LED lights indicating 1 LED1 ON when power ON 2 LED2...

Page 4: ...less than 2K Digital output 12 bit binary Resolution 5mV 10V default scope 1 2000 Precision Full scale 1 A D conversion time 1 scan time The analog digital conversion is completed by the END order Ch...

Page 5: ...6 The screwing torque of the terminal is from 0 5 to 0 6N m Fasten tight to prevent malfunction 7 Keep the redundant terminals empty 5 1 Suitable cable Use AWG25 16 to connect the output equipment The...

Page 6: ...nalog value If the data are not stored into D0 or D2 then D8112 D8113 can be simultaneously used on setting values and other orders such as timer counter 6 2 Examples of Applications Since the LX3V 2D...

Page 7: ...e analog values are stored in D8112 2 Since the data range is converted from A A into 2000 2000 therefore the precision of the analog output is no longer just 5mV Figure 6 1 If the digital range used...

Reviews: