SONIC DIGITAL MG Serie Reinigen
Operation
29
7.2
Switching on
DANGER
Ultrasonic oscillations. Risk of damage to hearing.
Wear ear protection.
All supply lines are ready for use.
The ultrasonic welding device is correctly maintained.
Apply mains voltage.
The ultrasonic generator is switched on and the internal power
supply unit is working.
The green LED POWER light is continuously lit on the front panel
of the housing. The generator is in standby mode.
If an MCU external control unit is connected, standby mode is
also indicated on the display: display 00 W.
The power supply has been established.
The ultrasonic welding device is ready.
On the generator:
Ultrasonic output can be started by pressing the TEST button on the front
panel of the generator's housing.
This button employs a "push" function, so the function only remains active
while the button is held down and then ends when the button is released.
Via the interface:
Ultrasonic output can be activated by applying signals to the FSGND and
FS24V control inputs.
Via the MCU control console:
Ultrasonic output is activated by pressing the ON/OFF button. The charac-
teristics of the ON/OFF button (push, toggle, disabled) can be changed un-
der SETTINGS. When "disabled" is set, no ultrasonic output is possible.
On the generator:
As the TEST button on the front panel of the housing employs a "push"
function, the function ends when the button is released.
Via the interface:
Ultrasonic output ends when the signals applied to the FSGND and FS24V
control inputs are removed.
Via the MCU control console:
Ultrasonic output is terminated by pressing the ON/OFF button
(if the "toggle" setting is being used).
Requirement
Switching on
Activating
ultrasonic output
Deactivating
ultrasonic output