background image

[email protected]

webdyn.com

V1.0 subject to changes | Webdyn © by Flexitron Group

32

ANNEX 1: Connection Quick Guide

1. Connectors/indicators

Power chord 

grommet 

(85 to 264VAC)

RS232/485

activity

Remote 

connection

Power

USB 2.0

DB9 

RS232/485

LTE SMA F 

antenna 

LTE/IP

LED

Status

Power (orange)

Power LED: lights up when the equipment is properly powered.

LTE signal/IP (blue)

Network LED: it lights up when the equipment gets the IP address from the 

operator. Solid blue when coverage is good, flashing blue when coverage is 

poor.

Remote connection 

(orange)

Connection LED: it lights up when the Reading Platform makes an IP 

connection against the modem to remotely read the meter.

RS232/485 activity 

(orange)

Serial Port LED: it lights up when data is received on the serial port, that is, 

data from the meter. It allows to check the proper functioning of the serial 

link with the meter.

Summary of Contents for Titan MTX-StarEnergy-M

Page 1: ...MTX StarEnergy M Software User Manual www webdyn com...

Page 2: ...gs 10 2 1 3 WAN Keep Online 11 2 2 LAN 13 2 2 1 LAN Basic Settings 13 2 3 Firewall 14 2 3 1 Firewall Authorized IPs 14 2 4 Serial Settings Serial portX 15 2 5 Other 17 2 5 1 Other AT Command 17 2 5 2...

Page 3: ...3 AT Commands 30 ANNEX 1 Connection Quick Guide 32 1 Connectors indicators 32 2 Start Up 33 3 Accesories 34 ANNEX 2 Configuration Examples 35 1 Example Scenario Configuration to access an IEC60870 5 1...

Page 4: ...ronica or its suppliers shall regardlessofanylegaltheoryuponwhichtheclaimisbased notbeliableforanyconsequential incidental direct indirect punitive or other damages whatsoever including without limita...

Page 5: ...used in remote reading scenarios for energy meters We support all users of our MTX modems and routers when they need it with free fast response and efficient technical support So if after reading this...

Page 6: ...which it has access to said web configuration environment 1 1 Minimum Requirements A PC with Windows 10 and with a web browser Chrome IExplorer Firefox and a USB port A USB cable to interconnect the P...

Page 7: ...elect option 1 and press ENTER Insert a SIM into the MTX StarEnergy M and connect the antenna After that power the device and then connect it to your PC through a USB cable Go to the Network Connectio...

Page 8: ...2 The default user is admin and the password is admin In Annex II of this manual you will find a step by step example of how to configure the MTX StarEnergy M for remote access to an Energy meter thr...

Page 9: ...e Version firmware version Public IP WAN IP address assigned from 2G 3G 4G connection if it is available GSM Module indicates the manufacturer and model of the internal GSM module of the MTX StarEnerg...

Page 10: ...e operator You should check with your GSM provider Username username of the operator You should check with your GSM provider Password operator s password You should check with your GSM provider Call c...

Page 11: ...onfiguration is finished press the SAVE CONFIG button to save the changes Remember that you must restart the device for the new changes to take effect 2 1 3 WAN Keep Online From this screen you can co...

Page 12: ...ates the IP address of the server against which to PING Period indicates how many minutes a check PING should be performed ADDITIONAL NOTES Once the configuration is finished press the SAVE CONFIG but...

Page 13: ...s will be assigned Only option available on this device IP Address local IP address of the emulated IP interface by default 192 168 1 2 IP Subnet Mask subnet mask IP Gateway Gateway IP address Leave b...

Page 14: ...will only be accessible from that IP address Authorized IP1 authorized IP address number 1 Authorized IP2 authorized IP address number 2 Authorized IP3 authorized IP address number 3 Router configurat...

Page 15: ...P as it arrives through the serial port A number for example 10 specifies that no data is sent if there is not a minimum period of 10ms without receiving data through the serial port This allows data...

Page 16: ...out specifies the time in seconds that must elapse to close an IP RS232 485 gateway in the case of no traffic on it ADDITIONAL NOTES Once the configuration is finished press the SAVE CONFIG button to...

Page 17: ...ck coverage identify the surrounding telephone cells etc On the other hand it is also possible to configure up to 5 special AT commands with which to configure the MTX StarEnergy M at startup time tha...

Page 18: ...e you can configure so that the MTX StarEnergy M connects to 2G 3G 4G after receiving an SMS command or make configuration changes readings of status by SMS command being able to specify the authorize...

Page 19: ...ered to execute SMS commands For example the AT command that performs a reset of the MTX StarEnergy M is AT MTXTUNNEL REBOOT If for example you specify the alias reset all you have to do is send an SM...

Page 20: ...toreset every certain number of hours Usually set to 24h in metering applications Auto reset at specific time select this option if you want the device to self reset at a specific time of day Auto res...

Page 21: ...OTES Once the configuration is finished press the SAVE CONFIG button to save the changes Remember that you must restart the device for the new changes to take effect 2 5 5 Other Remote Console TCP Ser...

Page 22: ...sword that will be requested after entering the user name SSH check the box if you want to use SSH instead of Telnet ADDITIONAL NOTES Once the configuration is finished press the SAVE CONFIG button to...

Page 23: ...gy M configuration each with a level of privileges From the admin user you will have access to all the MTX StarEnergy M configuration the user user will have access to the configurations that are sele...

Page 24: ...figuration is finished press the SAVE CONFIG button to save the changes Remember that you must restart the device for the new changes to take effect 2 5 8 Other Backup Factory You can perform a full b...

Page 25: ...use press the Upload button to upload the file ADDITIONAL NOTES You can also restore the MTX StarEnergy M to factory settings using a jumper housed inside next to the asim holder To do this you would...

Page 26: ...can be selected between SNMPv2c and SNMP v3 UDP port the standard UDP port for SNMP is 161 but you can specify the one that suits you best CustomOID allowsyoutochangetheEnterprise ProductOIDfromthede...

Page 27: ...TRAPS Community community field for sending TRAPS ADDITIONAL NOTES Once the configuration is finished press the SAVE CONFIG button to save the changes Remember that you must restart the device for th...

Page 28: ...rvice self signed certificates are generated automatically after reboot ADDITIONAL NOTES Once the configuration is finished press the SAVE CONFIG button to save the changes Remember that you must rest...

Page 29: ...thentication service Service console check the box if you want access by telnet or ssh Remote console to the device to use the authentication service Tacacs ADDITIONAL NOTES Once the configuration is...

Page 30: ...ll take approximately 2 minutes 3 AT Commands The MTX StarEnergy M firmware allows you to send AT commands directly to the internal modem QUECTEL through multiple interfaces By SMS Via Telnet SSH remo...

Page 31: ...ding the value of the MTX StarEnergy M configuration parameters For example you can check the APN field you have configured the speed of the serial port etc via AT commands Consult with Matrix Electr...

Page 32: ...perly powered LTE signal IP blue Network LED it lights up when the equipment gets the IP address from the operator Solid blue when coverage is good flashing blue when coverage is poor Remote connectio...

Page 33: ...en pass the power cables through the grommet located in the upper left corner of the front And connect the cables to the female terminal supplied with the equipment The distribution of signals in the...

Page 34: ...am waits for the Iberdrola platform to initiate communication Confirm the correct operation of the equipment indicated by the status of the LEDs on the front see table above Step 3 The device is suppl...

Page 35: ...fixed IP address will be used For exceptional maintenance cases the modem must be able to be configured remotely through SMS messaging as well as being able to carry out operations to consult coverag...

Page 36: ...X StarEnergy M configuration you must have the corresponding USB drivers installed as detailed in the SOFTWARE section of this manual Once the steps have been followed it is possible to access the MTX...

Page 37: ...e Network Selection section you can choose between auto GPRS 3G and 4G The auto option will make the modem choose the network based on the availability of the area In this example GPRS is selected bec...

Page 38: ...arEnergy M to have access by SMS for configuration changes remote resets etc go to the configuration section OTHER SMS control In this section we activate the AT box that will allow the sending of AT...

Page 39: ...et the MTX StarEnergy M will self reset When sending an SMS command as auto network the modem will be configured to work in auto mode 4g 3g 2g depending on availability and for example if we want to c...

Page 40: ...dule a daily reset every 24 hours to completely restart the terminal The MTX StarEnergy M also has that option To activate it just go to the menu Other Periodic autoreset and in the option Autoreset e...

Page 41: ...rebooted after about 30 40 seconds it is possible to check that the device has obtained an IP from the configuration menu from the Wan Status menu Additionally the MTX StarEnergy M has a series of LE...

Page 42: ...n com INDIA 803 804 8th floor Vishwadeep Building District Centre Janakpurt 110058 New Delhi Phone 91 1141519011 Email purchase india webdyn com PORTUGAL LusoMatrix Lda Av Coronel Eduardo Galhardo 7 1...

Reviews: