No RCC function:
Clock
:
2000-1-1
,
0:00:00
Æ
2099-1-1
,
23:59:59 (default value: 2013-1-1
,
AM
12:00:00)
No time zone and DST function
12/24Hr format (default value: 12Hr)
Temperature unit :C,F(default value:
℉
)
Barometric pressure unit: default hPa, it can be setting manually
B
、
Default parameter
1.Temperature&humidity indoor measuring: view one time every 30s
2.Temperature&humidity outdoor measuring:receiving 15seconds every 75s., the
transmitter will transmit every 10s.
3.Low voltage: measuring one time power on, measuring once every 1hr.The icon will
flash when low voltage appear.
1. Unit
switch
:
F=1.8*C+32
1hpa=0.75mmhg =0.02953inhg
1inhg = 25.4mmhg = 33.86hpa
1mmh g =0.03937inhg =1.333hpa
C
、
Default parameter alarming
High barometric pressure alarm value: 1050hpa/787.5mmhg/30.93inhg
Low barometric pressure alarm value
:
600pha/450mmhg/17.71inhg
Alarm value setting range: 300---1100hpa
8.86—32.48inhg
225---825mmhg
High alarm value channel 1 for out temperature
:
35
℃
/95
℉
Low alarm value channel 1 for out temperature
:
5
℃
/41
℉
High alarm value channel 1 for out humidity
:
75% Low alarm value channel 1 for out humidity
:
35%
High alarm value channel 2 for out temperature
:
40
℃
/104
℉
Low alarm value channel 2 for out temperature
:
0
℃
/32
℉
High alarm value channel 2 for out humidity
:
80% Low alarm value channel 2 for out humidity
:
30%
High alarm value channel 3 for out temperature
:
45
℃
/113
℉
Low alarm value channel 3 for out temperature
:
-5
℃
/23
℉
High alarm value channel 3 for out humidity
:
85% Low alarm value channel 3 for out humidity
:
25%
High alarm value for indoor temperature
:
30
/86
℃
℉
Low alarm value for indoor temperature
:
10
/50
℃
℉
High alarm value for indoor humidity
:
80% Low alarm value for indoor temperature
:
30%
Note: It could be setting by yourself for above alarm parameter.
Attention
:
a. Possible interference from other sources, the RCC can not receiving signals. In this