3.5.2 Temperature&humidity indoor alarm setting 

 

      

  

Temperature&Humidity alarm status(OFF)        Temperature&Humidity alarm status(ON) 

 

      

 

High temperature&humidity data setting            Low temperature&humidity data setting 

 

Key function: 

z

 Press 

MODE

,exit High/low temperature&humidity indoor alarm setting, 

enter into date mode 

z

 Press 

SET

,switch setting value: high/low temperature&Humidity indoor 

alarm (OFF) 

Æ

high temperature indoor alarm value

Æ

 high humidity indoor 

alarm value

Æ

 low temperature indoor alarm value

Æ

 low humidity indoor 

alarm value

Æ

exit 

z

 Press 

+/C/F/CLEAR

,short press add 1,long press more than 2 seconds 

would be a progressive increase 8Hz 

z

 Press 

-/MAX/MIN

,short press reduce 1, long press more than 2 seconds 

have a progressive decrease 8Hz 

Summary of Contents for WS1066

Page 1: ...Wireless Weather Station with Outdoor Sensor WS1066 ...

Page 2: ...CRIPTION 5 3 1 POWER ON RESET 5 3 2 TIME MODES DISPLAY 6 3 3 CLOCK ALARM MODES 7 3 4 BAROMETRIC PRESSURE MODES 9 3 5 AMBIENT TEMPERATURE HUMIDITY ALARM MODES 10 3 6 DATE MODES 13 3 7 MIN MAX VIEW MODES 15 3 8 RCC MODES 16 3 9 MOON PHASE 17 4 DEFAULT VALUE 17 5 TROUBLESHOOTING 19 6 TX4041 Transmitter 19 6 1 FEATURES 19 6 2 Operation 20 6 3 POWPER SUPPLY 20 6 4 ASSEMBLY SKETCH 20 6 5 ATTENTION 21 ...

Page 3: ...0 70 accuracy 1 C Display 0 and 70 when out of low high temperature range Sensor error display 9 Indoor humidity range 20 95 accuracy 5 Display 20 and 95 when out of low high humidity Sensor error display 10 Outdoor temperature range 40 70 accuracy 1 C Display 40 and 70 when out of low high temperature range Sensor error display 11 Outdoor humidity range 20 95 accuracy 5 Display 20 and 95 when out...

Page 4: ... cloudy and rain no flash as light rain 5 Mixture of cloudy and rain rain flash as rainstorm 6 Mixture of cloudy and snow no flash as light snow 7 Mixture of cloudy and snow flash as heavy snow 3 OPERATE DESCRIPTION 3 1 POWER ON RESET When the base station is powered up full display 3 seconds a short beep will sound then enter into RF receiving 3 minutes Press any keys except CHANNEL LIGHT SZ clos...

Page 5: ...ress MODE enter into clock alarm mode z Press SET for 2 seconds to enter into the time setting mode and then set time date alarm and time zone in correct order z Press C F CLEAR switch temperature C F when inquiry Max Min temperature you can clear MIN MAX data z Press MAX MIN inquiry Max Min temperature MINÆMAXÆexit z Press CHANNEL LIGHT SZ back light switch wireless channel receiving 1Æ2Æ3Ærepeat...

Page 6: ... than 2 seconds would be a progressive increase 8Hz press this key you can ON OFF alarm status z Press MAX MIN short press reduce 1 long press more than 2 seconds have a progressive decrease 8Hz press this key you can ON OFF alarm status z Press CHANNEL LIGHT SZ back light Notes 1 The setting mode will return to normal display mode while key idle 60s 2 The setting value flash with 1Hz 3 The clock ...

Page 7: ...this key you can ON OFF alarm status z Press MAX MIN short press reduce 1 long press more than 2 seconds have a progressive decrease 8Hz press this key you can ON OFF alarm status z Press CHANNEL LIGHT SZ back light Notes z 1 The setting mode will return to normal display mode while key idle 60s z 2 The setting value flash with 1Hz z 3 The clock alarm will not sound while setting z 4 When time ala...

Page 8: ...setting Key function z Press MODE exit barometric pressure alarm setting enter into outdoor high low temperature alarm mode z Press SET switch setting values high barometric pressure alarm ON ÆHigh kbÆHigh hundredsÆHigh decadeÆ High unitÆHigh decimal place ÆLow barometric pressure alarm ONÆLow kb ÆLow hundredsÆLow decadeÆLow unitÆLow decimal placeÆexit z Press C F CLEAR short press add 1 long pres...

Page 9: ...m is triggered the alarm will sound BiBiBi for 60seconds the alarm icon and alarm character will flash with 1Hz press any key to mute the alarm show alarm icon and high low alarm character accordingly on LCD 4 Any ringing alarm is subject to the latter one 5 The high low alarming only once alarm character will flash with 1Hz afterwards and the alarming will not triggered It will clear the high low...

Page 10: ...rt press add 1 long press more than 2 seconds would be a progressive increase 8Hz z Press MAX MIN short press reduce 1 long press more than 2 seconds have a progressive decrease 8Hz z Press CHANNEL LIGHT SZ back light Note 1 The setting mode will return to normal display mode while key idle 60s 2 The setting value flash with 1Hz 3 When barometric alarm is triggered the alarm will sound BiBiBi for ...

Page 11: ...oor alarm setting enter into date mode z Press SET switch setting value high low temperature Humidity indoor alarm OFF Æhigh temperature indoor alarm valueÆ high humidity indoor alarm valueÆ low temperature indoor alarm valueÆ low humidity indoor alarm valueÆexit z Press C F CLEAR short press add 1 long press more than 2 seconds would be a progressive increase 8Hz z Press MAX MIN short press reduc...

Page 12: ...rm icon and high low alarm character accordingly on LCD 4 Any ringing alarm is subject to the latter one 5 The high low alarming only once alarm character will flash with 1Hz afterwards and the alarming will not triggered It will clear the high low alarm value every 3 hours 3 6 DATE MODES Operation z Press MODE enter into time mode z Press SET long press 2 seconds enter into date setting z Press C...

Page 13: ...IN short press reduce 1 long press more than 2 seconds have a progressive decrease 8Hz z Press CHANNEL LIGHT SZ back light Note 1 The setting mode will return to normal display mode while key idle 60s 2 The setting value flash with 1Hz 3 When barometric alarm is triggered the alarm will sound BiBiBi for 60seconds the alarm icon and alarm character will flash with 1Hz press any key to mute the alar...

Page 14: ...ter into all modes setting z Press C F CLEAR switch temperature C F clear MIN MAX temperature and humidity values when view z Press MAX MIN view the MIN MAX temperature and humidity values MINÆMAXÆexit z Press CHANNEL LIGHT SZ back light switch wireless channels receiving 1Æ2Æ3Ærepeat Note 1 The setting mode will return to normal display mode while key idle 60s ...

Page 15: ...il 1 00 am next day if it can not receive valid signal on 1 00 am it will receive again on 2 00 am and so on If the receive cannot receive signals indoor the user can set the clock time manually Also moon phase data collection will not update when just receiving RCC signal it will update one hour later The conditions for the radio controlled time retreating a Press any key b No signals reception i...

Page 16: ...day of the Lunar month the end of month 270 degree 360 degree 4 DEFAULT VALUE A RCC parameter depend on the nations and regions EU DCF MSF Version Clock 2000 1 1 0 00 00Æ 2099 1 1 23 59 59 default value 2013 1 1 0 00 00 Time zone 12 Æ 12 MSF default 0 DCF default value 1 12 24Hr format default value 24Hr Temperature unit C F default value Barometric pressure unit default hPa it can be setting manu...

Page 17: ...50mmhg 17 71inhg Alarm value setting range 300 1100hpa 8 86 32 48inhg 225 825mmhg High alarm value channel 1 for out temperature 35 95 Low alarm value channel 1 for out temperature 5 41 High alarm value channel 1 for out humidity 75 Low alarm value channel 1 for out humidity 35 High alarm value channel 2 for out temperature 40 104 Low alarm value channel 2 for out temperature 0 32 High alarm value...

Page 18: ...1 No signal from remote sensor A There can be many reasons for this the following steps should help you troubleshoot this problem 1 1 Make sure that the batteries in the remote sensor are not depleted 1 2 Reduce the distance between transmitter and receiver 1 3 Remove the batteries from the base station and the remote sensor and reset the weather station in the right order as described in section ...

Page 19: ...econds 2 The sensor will transmit weather data every 10s while enter into normal learning mode 3 Low voltage indication view once when power on then one time every hour 4 All transmission data will setting and show on receiver s LCD 6 3 POWPER SUPPLY 1 2 1 5V AAA alkaline batteries 6 4 ASSEMBLY SKETCH 1 Take down the bottom case from the transmitter base station using PA3 16mm screw and ABS sleeve...

Page 20: ...rtment by selves 4 The channel setting by factory or user can switch the transmit channels which located on the bottom of battery cover Warning You should not dispose of this device with your household waste A selective collection system for this type of product is implemented by your local authorities Please contact your local authorities to find out how and where collection takes place These res...

Page 21: ...nterference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver ...