calculating de cits and run times again until the ACTIVE LED goes back to green
after the SLW DLY.
If you wish to change the de cit numbers, press and hold down either the UP or
DOWN button for 5 seconds. This allows you to use the DOWN button to reduce
the latest de cit for the zone to as low as 0 inches.
5.27.6
RUNTIME
This is the computed runtime based on the de cit for the next scheduled run.
5.27.7 TOTL
RUN
TOTL RUN is the total run time for each zone since the date shown (default date in
the SmartLine® controller is January 1, 2000 shown as 01/01/00). You can review
TOTL RUN for either the BASIC or SMART modes. After you select TOTL RUN with
the UP button, use NEXT to view the date when TOTL RUN accumulation began.
Use NEXT again to view the total run times for each zone.
You can use the NEXT and BACK buttons to move through the zones. After you go
through all the zone positions, use the NEXT button one more time to take you
back to the TOTL RUN screen.
5.27.8 CLR
TOTL
CLR TOTL is used to clear and reset the total run time for each zone shown in the
TOTL RUN menu.
From the CLR TOTL menu, press NEXT and the display will show KEEP. If you want
to clear the TOTL RUN time and reset the accumulation date, press either the UP or
DOWN button to display CLEAR. With CLEAR showing in the display, either press
NEXT or BACK or turn the dial to complete the clearing and resetting. This feature
will stop accumulations on a zone after 255 hours of cumulative zone run time.
5.27.9 CLR
DEF
To clear de cits, press NEXT. Use UP or DOWN buttons to select KEEP or CLEAR.
Press NEXT or BACK to exit CLEAR DEFICITS.
6.0 Troubleshooting the Controller
Total Reset Procedure for Controllers
🔗
Watering Cycle Pause Functions
🔗
Changing SLW or RFS5 Batteries
🔗
Faults
FAULT: ZONE XX INSUFFICIENT WATERING OPPORTUNITY
FAULT: NO RECENT CONTACT WITH WEATHER SENSOR
FAULT: ZONE XX OPEN, MV1 OPEN, MV2 OPEN
FAULT: ZONE XX SHORT, MV1 SHORT, MV2 SHORT