WIRELESS CONNECTIVITY & SENSORS
User manual Proteus-III
8.25. DIS_ManufacturerName: Configure the manufacturer name
Settings
index
Designation
Permissible
values
Default value
Permissions
Number
of
Bytes
20
See
description
"Default"
read/write
1-64
The user setting
specifies the content of the manufacturer name field
of the Device Information Service. The permissible characters are in the range of 0x20 - 0x7E
which are special characters (see ASCII table), alphabetic characters (a-z and A-Z), numbers
(0-9) and whitespace.
To add the content of the
to the DIS profile, please set
the corresponding Bit in the
8.25.1. Example 1
Set the manufacturer name to "Manufacturer1" using
with settings index 20
Start signal
Command
Length
Settings index
Parameter
CS
0x02
0x11
0x0E 0x00
0x14
0x4D 0x61 0x6E 0x75 0x66
0x61 0x63 0x74 0x75 0x72
0x65 0x72 0x31
0x0F
Response
: Successfully modified the setting.
Start signal
Command | 0x40
Length
Status
CS
0x02
0x51
0x01 0x00
0x00
0x52
8.25.2. Example 2
Request the manufacturer name of the DIS profile using
Start signal
Command
Length
Settings index
CS
0x02
0x10
0x01 0x00
0x14
0x07
Response
: Successfully read out the value "Default".
Order code 2611011024000