User manual Proteus-III
Start signal
Command
Length
Settings index
Parameter
CS
0x02
0x11
2 Bytes
1 Byte
(Length - 1) Bytes
1 Byte
Response (
Start signal
Command | 0x40
Length
Status
CS
0x02
0x51
0x01 0x00
1 Byte
1 Byte
Status:
0x00:
Request received, settings set successfully
0x01:
Operation failed due to invalid parameter
0x04:
Serious error, when writing flash. Try to factory reset or re-flash the device
0x05:
Supply voltage too low. Please apply correct supply voltage, reset and retry.
0xFF:
Operation not permitted
7.4.1.1. Example 1
Setting the advertising time
to 180 seconds.
Start signal
Command
Length
Settings index
Parameter
CS
0x02
0x11
0x03 0x00
0x07
0xB4 0x00
0xA3
Response:
Start signal
Command | 0x40
Length
Status
CS
0x02
0x51
0x01 0x00
0x00
0x52
Setting was set successfully.
7.4.1.2. Example 2
Setting the static pass key
to "123456".