background image

G

D

C

B

Torque

Screw Torque
  M4 

max. 2,0 Nm  (17.7 in-lb)

  M5 

max. 4,0 Nm  (35.4 in-lb)

  M10 

max. 23 Nm (203.6 in-lb)

Cable glands

  M16 

max. 1,5 Nm  (13.3 in-lb)

8)  Reposition gear box cover 

B

 and tighten screws 

C

 evenly.

45°

30°

15°

G

9)  Loosen the two screws 

G

 slightly. Aim luminaire 

(see illustration Swivel range: -45 ° + 90 °),  
tighten screws 

G

 firmly (max. 23 Nm (203.6 in-lb)). 

Summary of Contents for FLC210 LED

Page 1: ...ance Instructions for Projector FLC210 LED FLC210 LED Profile Projector Notice In case the luminaire is equipped with an optio nal available surge protector the function can get tested if the signal L...

Page 2: ...n Attention Switch off mains electrical supply prior to installing and connecting the luminaire Do not open luminaire while mains supply is switched on Notice If the luminaire is modified by anybody o...

Page 3: ...12 17 IP66 FLC210 LED 120 277V 60 Hz 139 XXXX SOE XXXXXXX LED 3000K XXW item no XXX G D C B 5 Feed mains supply cable D through cable gland E 8 8 0 10V ON OFF L N L N D D E F 6 Connect to the corresp...

Page 4: ...ft distance O R Q Y T1 T2 T3 N Only for PP Version 2 1 Gobo projector GP Pull the gobo cassette out of the gobo holder Loosen screw P on the gobo cassette unfold the cassette and place gobo M motif up...

Page 5: ...in lb M10 max 23 Nm 203 6 in lb Cable glands M16 max 1 5 Nm 13 3 in lb 8 Reposition gear box cover B and tighten screws C evenly 45 30 15 G 9 Loosen the two screws G slightly Aim luminaire see illust...

Page 6: ...4 3 4 5 4 7 4 9 4 2 4 4 4 8 1 1 1 3 1 5 1 7 1 9 1 2 1 4 1 8 1 6 R R G G B B W W 1 3 5 6 7 4 1 4 2 4 3 4 5 4 4 1 1 1 2 1 3 1 5 1 4 1 1 1 2 1 3 1 5 1 4 C C W W Terminal assignment Luminaire 3 Terminal...

Page 7: ...t legislation Notice If the luminaire is modified by anybody other than the original manufacturer then the warranty will no longer be valid and shall become the full responsibility of the modifying pe...

Page 8: ...off the mains electrical supply 4 Connect cable via main cable gland and connect to the appropriately marked terminals For through wiring version an additional screw connection can be used To do this...

Page 9: ...ains electrical supply 4 Connect cable via main cable gland and connect to the appropriately marked terminals For through wiring version an additional screw connection can be used To do this remove th...

Reviews: